DLPT2+
Operating Instructions
39
Cord Test
Earth continuity, insulation resistance as above.
Check for Live and Neutral open circuit, short
circuit or reversed polarity.
RCD Test
Display Range
I
Δ
n - 0ms to 500ms
5I
Δ
n – 0ms to 40ms
Measuring Range I
Δ
n - 10ms to 500ms
5I
Δ
n – 10ms to 40ms
Accuracy
± 2ms
Test Current
I
Δ
n – 30mA
5I
Δ
n – 150mA
Current Accuracy -0, +10%
Factory Set Pass/Fail limits
Earth
Continuity
Insulation
Resistance
Leakage
Class I
0.2 ohms
1.0Mohm
0.75 / 3.5
Class II
n/a
2.0Mohm
0.25mA
Cord
0.2 ohms
1.0Mohm
n/a
3-Phase
0.2 ohms
1.0Mohm
3.5mA
Environmental rating
IP Rating IP40
Operating temperature range 0°C to 40°C, without
moisture condensation.
Storage temperature range –25° to 65°.
Note: Batteries should be removed prior to
storage.
Overvoltage category 300V CAT II