DLPT2+
Operating Instructions
36
E.g.: Silicon Labs CP210x USB to UART
Bridge(COM14)
Select the correct COM port.
Click on Download. A progress bar will appear.
On the DLPT2+ in order to transfer the entire test
storage area to PC press and hold the RECALL key
for 5 seconds. The data will be transmitted using the
USB interface.
When all data has been captured and stored the
progress bar will disappear and you will be asked
where to save the data.
Once the file is saved you may click the "Open"
button to open the document with default
application.
For example, if you saved the file in .csv format (the
default) then it may open using a spreadsheet
application.
4.5
Printing Test Results
In order to print a test label press the PRINT Key
when the test sequence has been completed or
when the test result is being reviewed. The printer
must be attached before the PRINT Key is pressed.
In order to save power the DLPT2+ will turn the
printer on and off when required.
4.6
Setting the Real Time Clock
Setting time and date:
Ensure that the DLPT2+ is powered off. Press and
hold the RECALL key and then press simultaneously
the class I and class II keys to power on the tester.
The date format and time format is shown as
follows:
MM.DD = month (1-12). Day (1-31)
YYYY = year
HH.mm = hours (0-23).minutes (0-59)
SS = seconds (0-59)
Press the class I key to select a date field and time
field.
A flashing digit shows that this field can be set.
Summary of Contents for DLPT2+
Page 1: ......
Page 9: ...DLPT2 Operating Instructions 9 Figure 1 DLPT2 Front View ...
Page 11: ...DLPT2 Operating Instructions 11 Figure 4 Testing CLII appliances no mains leakage ...
Page 12: ...DLPT2 Operating Instructions 12 Figure 5 Testing CLI appliances mains leakage ...
Page 13: ...DLPT2 Operating Instructions 13 Figure 6 Testing CLII appliances mains leakage ...
Page 14: ...DLPT2 Operating Instructions 14 Figure 7 Testing IEC Leads ...
Page 15: ...DLPT2 Operating Instructions 15 Figure 8 Testing Installation RCD ...
Page 16: ...DLPT2 Operating Instructions 16 Figure 9 Testing Plug Top RCD ...