DEVIlink™ CC
Installation Guide
22
•
Forecasting method:
When activating the forecast
method, the system will automatically predict the heat-
ing start-up time necessary to reach the desired room
temperature at the desired time (all heat emitter types).
•
Maximum floor temperature:
The default setting is
35 °C (electrical floor heating).
•
Regulation type:
Only in connection with electrical
heating systems.
Note!
Use pincode [0044] to change between the following
regulation types:
Room sensor
(regulates only by room temperature) - if
only DEVIlink™ RS is fitted (hydronic floor heating) or
DEVIlink™ RS + DEVIlink™ FT (electrical heating).
Floor sensor
(regulates only by floor temperature ) - if only
DEVIlink™ FT/S is fitted.
Combined room/floor
(ensures min. floor temperature and
regulates room temperature in parallel) - DEVIlink™ RS +
DEVIlink™ FT/S is fitted.
In case of hydronic floor heating, be aware if a certain max.
floor temperature is given by the floor manufacturer. This
can be assured by fitting a thermostatically controlled mix-
ing shunt.