troubleshooting
Error Code
Reason
Corrective Action
EA
Coins present in the
hopper when the machine
is turned on or defective
coin sensor
Press the "Start/Stop"
button to clear the error
E1-E8
Counting sensor error
(May have collected dust,
or is obscured by a foreign
object)
Clean the Counting sensor
using an Air Duster Can
Ensure coin outlet
openings are free of any
obstructing object
E9
Running sensor error
Clean the running sensor
(refer to the maintenance
section).
Inspect the interior of the
machine for possible
foreign material that may
be preventing the coin
platter from rotating.
If the error persists, contact DETECK Technical Support Team
Problem description
Cause/Action
Does not function after the unit has been
turned on
Ensure the power cord is connected
properly. Unplug the machine from any
power source and replace the fuse
(5x20mm, 0.5A) located on the bottom of
the machine
Inaccurate counting
Clean counting sensors using an air
duster or microfiber cloth. Refer to the
maintenance section.
Coins are jammed
Turn off the machine. Remove the three
housing screws and carefully lift up the
housing. Remove any foreign objects or
coins from the distribution place. Refer to
the maintenance section