background image

9

8

Note the meaning of below terms used in the manual: 
THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS

Note the meaning of below terms used in the manual: 

THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS

1 x Honeycomb cell for ampules 
1 x Round metallic dish 
1 x Beaker with lid 
1 x Electrodes for recording on water 

1 x External Quantum light effect unit

1 x External Antenna unit
1 x Computer interface «BS-8» with «EAVPRO 5.0» program
1 x Power supply unit
1 x Cables set
1 x Documentation set

3. RULES FOR USING THE DEVICE

Operating conditions

Static electricity may adversely affect functioning, so it is good to cover the working area with 

an antistatic mat and avoid carpet that tends to accumulate static charge. Shoes should be worn 
as bare feet can also accumulate static charge. Wooden chairs are best, covered with cotton fabric, 
not synthetic. High frequency electrical equipment should not be close by, not computers and radio 

equipment. Humidity and moisture can adversely affect the DEVITA PROFESSIONAL, so this must 

be kept to a minimum.

Safety measures

Do not connect the device to an AC adapter with a damaged power cord. Do not attempt to 

repair the device yourself. If a fault occurs, please contact a service centre.

 

4. SETTING UP THE DEVICE - BASIC SETUP

 

The device can be set up relatively easily by following these simple instructions:

1. Connect the AC adapter to the «12V» socket on the device (see Fig.3, number 2). The polarity 

of the voltage does not matter.

2. Insert the AC adapter into a wall socket with 220V voltage.

3. Turn on the device with the «12V» switch. On the front of the device, the «PROB» LED should 

illuminate.

Aſter finishing work with visitors, do not forget to switch off the device with the «12V» switch and 

unplug the AC adapter.

Warning:

 The «LOW POWER» LED indicates a reduced voltage power supply. In this case, the 

exact correspondences of the technical parameters of the apparatus to the indicated standards 

are not guaranteed.

5. EXPLANATION OF THE BASIC MODULES 

 

OF THE PROFESSIONAL

The «DeVita Professional» device includes the following basic modules (Fig. 1).

1-Measuring  Module

 – used for measuring the level of the body's condition according  

to Dr. Voll and VRT testing according to Dr. Schimmel.

2-Electronic Selector Module

 

– contains 22, 800 digitized remedies of a wide variety  

of homeopathics, as well as a further 25, 200 empty memory slots to input your own remedies, 

foods and homeopathic remedies. 

3-Wellness

 

Module–Therapy

 

Unit

 

– controls for using Electroacupuncture, 

Electromagnetic and Quantum effects.

4-Wellness

 

Module-Bioresonance

 

Unit

 

–  controls  for  using  Bioresonance  effect 

 

on the body. On the right side of the device are sockets to connect the individual modules  

together (Fig. 2).

Fig. 1: External view of the DEVITA PROFESSIONAL

1

3

4

2

Summary of Contents for DeVita Professional

Page 1: ...Note the meaning of below terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS OF HEALTH STATUS...

Page 2: ...Note the meaning of below terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS OF HEALTH STATUS...

Page 3: ...IX Manufacturer EC Declaration of Conformity CONTENT 1 INTRODUCTION 2 SPECIFICATION The measure mode Electroacupuncture effect mode Electromagnetic effect mode Electronic selector ES Quantum effect re...

Page 4: ...the measure mode measurements can be made according to the methods of Dr Voll and Dr Schimmel Parameters used are Conductivity indicator ranges from 0 to 100 Accuracy of measurement 1 Voltage between...

Page 5: ...SETUP The device can be set up relatively easily by following these simple instructions 1 Connect the AC adapter to the 12V socket on the device see Fig 3 number 2 The polarity of the voltage does no...

Page 6: ...e will refer to it as the Probe from here on first you must press the PROBE button on the MEASURE panel see Fig 4 number 4 In this case the PROB LED illuminates green Fig 4 number 2 Then on the THERAP...

Page 7: ...ECTING THE ELECTRONIC SELECTOR 2 Connect SEL to PASSIVE together with short wire 3 Connect PROBE to connector The procedure is summarized in Diagram 2 below 1 On the THERAPY panel set the THERAPY DIAG...

Page 8: ...resonator honeycomb with ampoules 1 On the measures panel press the PROBE button Fig 4 number 4 In this case the PROB LED illuminates 2 On the THERAPY panel set the THERAPY DIAGNOSTICS button to the D...

Page 9: ...y from the list then you simply enter the number zero 0 and it will be erased ELECTRONIC SELECTOR 6 2 ELECTRONIC SELECTOR ES On the PREPARATIONS display the message 01 N_ _ _ _ _ N should appear On th...

Page 10: ...did Voll and Schimmel We use a pressure of about 100 150 grams The pressure will differ according to age the condition of the skin whether they have psoriasis etc There are 10 fingers and we are free...

Page 11: ...rce for an electrode of 3 mm diameter 60 110 gram force for an electrode of 4 mm diameter 70 200 gram force The electrode we use on the Professional is usually 3 mm Moving to the measurement plateau t...

Page 12: ...and it is impossible to find any energy points 5 Could have very dry skin or skin affected with eczema or psoriasis 6 5 IS IT POSSIBLE TO TEST DIFFERENT THINGS AT THE SAME TIME In order not to kill t...

Page 13: ...left and right It is possible to identify whether organ systems have inflammation or degeneration using this method and then using Bioresonance VRT testing to identify the specific organs involved Se...

Page 14: ...the 4 measures or quadrants to identify pathology This will become clearer as we study the numbers on Diagram 10 below Diagram 9 Quadrant Measuring Relationships Specifically the top diagram shows an...

Page 15: ...ond electrode the harmonious frequencies being positively fed back positive feedback whilst the disharmonious frequencies are negatively fed back i e inverted negative feedback AN EXAMPLE OF INFLAMMAT...

Page 16: ...ng their healing process as well as inverting and neutralizing any pathological frequencies from the visitor and their body fluids Basic effect is carried out using the hand and foot electrodes before...

Page 17: ...T BRT into the left hand and the other hand electrode from the OUTPUT BRT into the right hand Energy will then flow from the strong to the weak therefore strengthening the right side of the body in th...

Page 18: ...ILS 1 Connect the honeycomb or resonator and hand electrode with the INPUT BRT connector body fluids 2 Connect resonator and hand electrode to OUTPUT BRT connector water alcohol 1 2 INVERSION ON INTER...

Page 19: ...ould adjust the frequency to 100 Hz in order to cut out the first 100 Hz range as the potency D3 is higher than 100 Hz This will allow frequencies between 101 and 1 000 Hz to penetrate but cut out the...

Page 20: ...use the ve polarity or button DOWN 8 When the button is DOWN on the Sinusidal wave we use this setting when there is no degenerative process but the problem is more functional See Diagram 18 for a su...

Page 21: ...s own frequencies Our most important energy source is light and the entire spectrum of colours is derived from light Sunlight which contains all the wavelengths consists of the entire electromagnetic...

Page 22: ...the skin at a speed of 1 2 cm sec In COMPLEX EFFECT MODE Quantum light is used half the time of Electromagnetic Effect 19 Zones can be used on body 7 5 COMPLEX EFFECT MODE COMPLEX EFFECT is a synthesi...

Page 23: ...t to transfer contaminated energetic information to the sugar pills Small plastic bag and sticker to place the homeopathics and label them for the visitor The potency of the homeopathic copy will be e...

Page 24: ...st 3 days in the visitor as this will get stored in the PLASMA MEMORY 4 Choose the remedies from the ELECTRONIC SELECTOR that you want on the various levels each remedy that you choose will have separ...

Page 25: ...accordance with the obligatory state standards effective technical documentation and classified as fit for operation Technical control check mark Seal here _____________________ ______________________...

Page 26: ...w terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS OF HEALTH STATUS Note the meaning of below terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS...

Page 27: ......

Reviews: