Note the meaning of below terms used in the manual: 
THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS

Note the meaning of below terms used in the manual: 

THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS

1. INTRODUCTION

For the first time the thought of energy presence in a human body and of health dependence 

on its circulation was expressed by ancient Esculapians of China, India, and Egypt. Every human 

organ  emits  certain  resonance  frequencies.  Under  the  influence  of  unfavourable  external 

factors, modern life full of stresses, bad environment, its frequencies deviate from their natural 
parameters, and a risk of reduction of body defences can occur.

Device DeVita Professional is a unique development in the field of good health support without 

medication. DeVita Professional soſtly and safely influences on the human body without disturbing 

its energy balance either in the whole or locally.

The most important advantage of DeVita Professional is the availability of device for measuring 

the level of the body's condition and programs for health support by sessions. This allows you to 
choose an individual prophylactic course for each person.

Wellness technique is a healthy diet, moderate physical exercises, fresh air, and cessation from 

harmful habits - largely reduces the risk of various diseases. However, in today’s world it is not 
always possible to commit oneself to the concept of wellness consistently. This is especially true 
for large cities, with their constant stresses, rapid way of life and a poisoned environment.

DeVita-Professional devices are designed to help the body to maintain vitality at a high level, to 

work effectively even in an unfavourable external environment, to preserve youth and beauty for 

years to come.

2. SPECIFICATION

The measure mode

In the measure mode, measurements can be made according to the methods of Dr. Voll  

and Dr. Schimmel. Parameters used are:

• Conductivity indicator ranges from 0 to 100 
• Accuracy of measurement, ± 1%
• Voltage between the measure probe and hand electrode is 1.25 V
• Measure current is not greater than 12.5 mkA

• Sound can be turned on or off in the measure mode

• LED lights for «LOW POWER» and «VEGATEST» mode

Electroacupuncture effect mode

In the Electroacupuncture effect mode, the parameters used are:

• The Output signal can be of positive polarity, negative polarity, bipolar, bipolar inverse
• Pulse duration at level of 0.5 = 1 ms
• Range of pulse repetition rate, 0.1-99.99 Hz
• Maximum error of frequency setting, not more than ± 5%

Electromagnetic effect mode

In the electromagnetic effect mode, the parameters used are:

• Output signal is a bipolar pulse bundle with a high frequency
• Range of pulse packet repetition rate, 0.1- 99.99 Hz
• Maximum frequency error of frequency setting, not more than ± 5%

Electronic selector (ES)

The Electronic Selector has many digitized remedies – the specifications are:

• 22800 digitized remedies of a wide variety of homeopathics
• A further 25200 empty memory slots to input your own remedies, foods and homeopathic 

remedies

• The maximum number of remedies that can be given simultaneously to the visitor is 18

Quantum effect regime

The specifications for the Quantum effect regime are:

• Dynamic range, 0.1-99.99Hz
• Maximum error of frequency setting, not more than ± 5%
• Optic range, nm 468, 525, 590, 660, 880

Power

• AC adapter 220V/50Hz 12V/0.5A
• Current consumption, not more than, 0.33A

Operating

 

conditions

• Ambient temperature from 10 to 35°C
• Relative humidity 80% at 25 °C

Other specification

• PC connection assembly interface “BS-8”
• Average service life, not less than 5 years

• Dimensions (without packaging), mm 480 х 330 х 140

• Weight: without accessories and spare parts 3 kg; as a whole unit 7 kg

Package Contents

1 x Device «DeVita Professional» 
2 x Brass hand electrodes cylinders
2 x Brass foot electrode plates
1 x Universal measure probe

Summary of Contents for DeVita Professional

Page 1: ...Note the meaning of below terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS OF HEALTH STATUS...

Page 2: ...Note the meaning of below terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS OF HEALTH STATUS...

Page 3: ...IX Manufacturer EC Declaration of Conformity CONTENT 1 INTRODUCTION 2 SPECIFICATION The measure mode Electroacupuncture effect mode Electromagnetic effect mode Electronic selector ES Quantum effect re...

Page 4: ...the measure mode measurements can be made according to the methods of Dr Voll and Dr Schimmel Parameters used are Conductivity indicator ranges from 0 to 100 Accuracy of measurement 1 Voltage between...

Page 5: ...SETUP The device can be set up relatively easily by following these simple instructions 1 Connect the AC adapter to the 12V socket on the device see Fig 3 number 2 The polarity of the voltage does no...

Page 6: ...e will refer to it as the Probe from here on first you must press the PROBE button on the MEASURE panel see Fig 4 number 4 In this case the PROB LED illuminates green Fig 4 number 2 Then on the THERAP...

Page 7: ...ECTING THE ELECTRONIC SELECTOR 2 Connect SEL to PASSIVE together with short wire 3 Connect PROBE to connector The procedure is summarized in Diagram 2 below 1 On the THERAPY panel set the THERAPY DIAG...

Page 8: ...resonator honeycomb with ampoules 1 On the measures panel press the PROBE button Fig 4 number 4 In this case the PROB LED illuminates 2 On the THERAPY panel set the THERAPY DIAGNOSTICS button to the D...

Page 9: ...y from the list then you simply enter the number zero 0 and it will be erased ELECTRONIC SELECTOR 6 2 ELECTRONIC SELECTOR ES On the PREPARATIONS display the message 01 N_ _ _ _ _ N should appear On th...

Page 10: ...did Voll and Schimmel We use a pressure of about 100 150 grams The pressure will differ according to age the condition of the skin whether they have psoriasis etc There are 10 fingers and we are free...

Page 11: ...rce for an electrode of 3 mm diameter 60 110 gram force for an electrode of 4 mm diameter 70 200 gram force The electrode we use on the Professional is usually 3 mm Moving to the measurement plateau t...

Page 12: ...and it is impossible to find any energy points 5 Could have very dry skin or skin affected with eczema or psoriasis 6 5 IS IT POSSIBLE TO TEST DIFFERENT THINGS AT THE SAME TIME In order not to kill t...

Page 13: ...left and right It is possible to identify whether organ systems have inflammation or degeneration using this method and then using Bioresonance VRT testing to identify the specific organs involved Se...

Page 14: ...the 4 measures or quadrants to identify pathology This will become clearer as we study the numbers on Diagram 10 below Diagram 9 Quadrant Measuring Relationships Specifically the top diagram shows an...

Page 15: ...ond electrode the harmonious frequencies being positively fed back positive feedback whilst the disharmonious frequencies are negatively fed back i e inverted negative feedback AN EXAMPLE OF INFLAMMAT...

Page 16: ...ng their healing process as well as inverting and neutralizing any pathological frequencies from the visitor and their body fluids Basic effect is carried out using the hand and foot electrodes before...

Page 17: ...T BRT into the left hand and the other hand electrode from the OUTPUT BRT into the right hand Energy will then flow from the strong to the weak therefore strengthening the right side of the body in th...

Page 18: ...ILS 1 Connect the honeycomb or resonator and hand electrode with the INPUT BRT connector body fluids 2 Connect resonator and hand electrode to OUTPUT BRT connector water alcohol 1 2 INVERSION ON INTER...

Page 19: ...ould adjust the frequency to 100 Hz in order to cut out the first 100 Hz range as the potency D3 is higher than 100 Hz This will allow frequencies between 101 and 1 000 Hz to penetrate but cut out the...

Page 20: ...use the ve polarity or button DOWN 8 When the button is DOWN on the Sinusidal wave we use this setting when there is no degenerative process but the problem is more functional See Diagram 18 for a su...

Page 21: ...s own frequencies Our most important energy source is light and the entire spectrum of colours is derived from light Sunlight which contains all the wavelengths consists of the entire electromagnetic...

Page 22: ...the skin at a speed of 1 2 cm sec In COMPLEX EFFECT MODE Quantum light is used half the time of Electromagnetic Effect 19 Zones can be used on body 7 5 COMPLEX EFFECT MODE COMPLEX EFFECT is a synthesi...

Page 23: ...t to transfer contaminated energetic information to the sugar pills Small plastic bag and sticker to place the homeopathics and label them for the visitor The potency of the homeopathic copy will be e...

Page 24: ...st 3 days in the visitor as this will get stored in the PLASMA MEMORY 4 Choose the remedies from the ELECTRONIC SELECTOR that you want on the various levels each remedy that you choose will have separ...

Page 25: ...accordance with the obligatory state standards effective technical documentation and classified as fit for operation Technical control check mark Seal here _____________________ ______________________...

Page 26: ...w terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS OF HEALTH STATUS Note the meaning of below terms used in the manual THERAPY HEALTH IMPROVEMENT and DIAGNOSTICS PROGNOSIS...

Page 27: ......

Reviews: