Note the meaning of below terms used in the manual:
THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS
Note the meaning of below terms used in the manual:
THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS
Socets (Fig. 2)
1 - «INPUT BRT» – Bioresonance Unit Input;
2 - «OUTPUT BRT» – Bioresonance Unit Output;
3 - «SEL» – Electronic Selector output;
4 - «ACTIVE» – active electrode Output.
Connected to the PROBE;
5 - «PASSIVE» – 1st passive electrode Outputs;
6 - «PASSIVE» – 2nd passive electrode Outputs;
7 - «PROBE» – universal Probe Input connection.
Key and Socets (Fig. 3)
1 - POWER ON/OFF «12V» Switch
2 - Power supply unit input «12V»
3 - QUANTUM light connector
4 - ANTENNA connector for Electromagnetic effect
5 - BS-8 interface block connector – for computer connection
Fig. 2: Right side view
1
2
3
4
5
6
7
8
9
10
11
Abduction or quadrant section
8 - «LH»– «leſt hand»
Output for quadrant leads;
9 - «RH» – «right hand»
Output for quadrant leads;
10 - «LF» – «leſt foot»
Output for quadrant leads;
11 - «RF» – «right foot»
Output for quadrant leads.
4
3
5
Fig. 3: Rear view
1
2
6. MEASURE MODE – BASIC PRINCIPLES
6.1 MEASURE
Setting up the device for measure
In order to begin using the bioresonance measures using the Universal probe (we will refer to it
as the «Probe» from here on), first you must press the «PROBE» button on the «MEASURE»
panel
(see Fig. 4, number 4).
In this case, the «PROB» LED illuminates green (Fig. 4, number 2).
Then on the «THERAPY» panel (Fig. 6), set the «THERAPY/DIAGNOSTICS» button to the
«DIAGNOSTICS» position.
To work with the Selector to choose the different organ systems and remedies, it is necessary
to do the following:
1. Connect a wire from the «PASSIVE» socket (Fig. 2) to a brass hand electrode
2. Connect a short wire from the selector output «SEL» to the second socket «PASSIVE» (Fig. 2)
3. Insert the Measure probe (Fig. 5) into the socket «PROBE» (Fig. 2).
The DeVita Professional device allows for
measure according to the methods developed
by Dr. Voll and Dr. Schimmel. The «
MEASURE»
panel to control the measure mode is shown
in Fig. 4.
There are three indicator LED lights on
the leſt of the panel. «PROBE» are normally
GREEN in colour accept when in
Electroacupuncture mode when it will turn
RED. The first LED light (no. 1) is the LOW
POWER indicator if the correct voltage is
not being maintained. The second LED light
(no. 2) will be green when the PROBE button
is pressed on the panel. The third LED light
is the VEGATEST light which will be green
when the device is in the VRT MEASURE mode
(pressing the second button on the Measure
Probe , fig. 5) and switching to DIAGNOSTICS
on the
«THERAPY»
panel (see Fig. 6).
4
6
5
7
8
Fig. 4: «MEASURE» panel
1
3
2