DIRECT-VENT GAS FIREPLACE

EVDDVF36PN and EVDDVF36STN

®

OPERATING
GUIDELINES AND
MAINTENANCE
INSTRUCTIONS

When lit for the first time, the appliance may
emit a slight odor for about 16 - 24 hours. This
is normal and is due to the “curing” of the logs
and the “burn-in” of internal paints and lubri-
cants used in the manufacturing process.
Keep compartments, logs, burners, and area
surrounding the logs clean by vacuuming or
brushing at least twice a year. Temporary
removal of the log set may ease the cleaning
of the burner and electrode assembly. In
cleaning, take care not to alter the electrode or
burner location. Be sure appliance is cool
before each maintenance session.

 CAUTION: The appliance and

logs can get very hot - Handle
only when cool.

 WARNING: Do not operate

appliance with panel(s) and glass
removed, cracked, or broken. Re-
placement of the panel(s) should
be done by a licensed, qualified
service person.

 WARNING: Make certain wires

and gas lines are not touching
the underside of the firebox.

 CAUTION: If the glass breaks,

be cautious of fragments on the
floor. Keep children away from
the area. Do not operate the unit.
Use proper safety gloves to re-
move the broken glass door. Dis-
card safely. A glass door kit can
be ordered through your local
distributor. Do not substitute
other material for the glass.

 WARNING: Children and

adults should be alerted to the
hazards of high surface tempera-
tures, and to stay away from the
appliance to avoid burns or cloth-
ing ignition. Young children
should be carefully supervised
when they are in the same room
as the appliance.

 WARNING: Have a qualified

agency periodically inspect the
vent system at the start of each
heating season, for any obstruc-
tion which may hinder its normal
operation. Never obstruct the
flow of combustion and ventila-
tion air. Keep the front of the
appliance clear of all obstacles
and materials.

 WARNING: Do not abuse,

strike, or slam the glass doors.

 CAUTION: Label all wires

prior to disconnection when ser-
vicing controls. Wiring errors
can cause improper and danger-
ous operation.

For further operating guidelines, contact
your authorized dealer.

Any household glass cleaner may be used to
clean the glass panel. Do not use abrasive
cleaners as this may damage the glass. Clean
glass only when cool.

 WARNING: Turn off gas and

wall switch before servicing ap-
pliance. Any safety screen or
guard removed for servicing the
appliance must be replaced prior
to operating the appliance.

BURNER REMOVAL

 CAUTION: Before proceed-

ing, make sure the entire unit is
cool.

1.

Remove the top and bottom louvers and
screen. Open the glass door (left or right
side).

2.

Carefully remove the log set.

3.

Remove the screw that attaches the
burner to the bracket.

4.

Slide the burner towards the front of
the unit, lift, and remove from the fire-
box.

5.

To reinstall the burner, slide the burner
towards the rear of the unit and secure
burner to bracket with screw.

 CAUTION: Make certain the

orifice is inside the venturi tube's
air shutter, see Figure 50, page 19.

6.

Replace the log set, close door with
latches, and attach screen and louvers.

BURNER FLAME
ADJUSTMENT

Continued

Summary of Contents for Vanguard EVDDVF36PN

Page 1: ...gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier SAVE...

Page 2: ...d Back of Surround Figure 2 EVDDVF36STN See Thru Dimensions Left Side Surround Right Side Surround Rating Plate Location Left Side Surround Right Side Surround GLOSSARY OF TERMS Chase A box like enclo...

Page 3: ...gas approved for use in this gas appliance NOTICE Check local building codes for area requirements be fore installing this appliance This appliance when installed must be elec trically grounded in ac...

Page 4: ...ock re quired air spaces with insula tion or any other material Do not obstruct the effective opening of the appliance with any type of facing material MANTEL CLEARANCES Woodwork such as wood trims ma...

Page 5: ...ting terminals into a wall or siding If installing on vinyl siding a vinyl sid ing standoff must be used see Figure 19 page 9 Install horizontal venting with a 1 4 rise for every 12 of run toward the...

Page 6: ...aved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 2...

Page 7: ...t is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical...

Page 8: ...the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide strai...

Page 9: ...of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained...

Page 10: ...al V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting FGFVK Vent Kit Shown Horizontal Termination Configurations Figures 21 through 23 show different con figurations...

Page 11: ...90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 4 max 6 min 8 max 7 min 10 max 8 min 15 max 20 max 20 max Figure 23 Horizontal Termination Configuration for Rigid Venting Using Two 90 Elbows w...

Page 12: ...ances air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do not pack air spaces with insulation Also note maxi mum vertical rise of the venting sys tem a...

Page 13: ...ort box vertically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corne...

Page 14: ...tion With No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Fi...

Page 15: ...shing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustabl...

Page 16: ...he blower system will not flow properly WARNING Disconnect all electrical power to the fireplace Be careful of burrs and sharp edges BLOWER SPEED CONTROL INSTALLATION 1 Place speed control switch asse...

Page 17: ...em at test pressures equal to or less than 1 2 psig 3 5 kPa 1 Install a sediment trap between the in coming gas line and the gas control valve see Figure 40 The sediment trap should extend down the ce...

Page 18: ...to prevent damage to glass or refractory 1 Remove top and bottom louvers by si multaneously pulling both top end spring latches towards the center of the applianceuntiltheyaredisengagedfrom locating...

Page 19: ...d during shipping and han dling If this is the case some minor adjust ments may be necessary and should be done by a qualified technician To access the elec trode the glass door must be opened The pro...

Page 20: ...ng ignition Young children should be carefully supervised when they are in the same room as the appliance WARNING Have a qualified agency periodically inspect the vent system at the start of each heat...

Page 21: ...tes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation in column one If you don t smell gas go to the next step 7 Turnequipments...

Page 22: ...iginalreplacementpart s call DESA International s Technical Ser vice Department at 1 800 323 5190 for re ferral information When calling DESA International have ready your name your address model and...

Page 23: ...Replace control valve see Replacement Parts page 27 5 Tighten wires or replace electrode 6 Check that the main power is on and that all wire connections are made correctly to the ignition module see W...

Page 24: ...oved from line Have gas line checked by local pro pane LP gas company 2 Clean burner or replace burner orifice 1 Adjust the log set so that the flame does not excessively impinge on it 2 Inspect the o...

Page 25: ...ss too loose and air tight gasket leaks in corners after usage 6 Improper vent cap installation 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Bu...

Page 26: ...overplate andmillivoltwires are supplied with the appliance If wires need replacing use proper gauge Millivolt Wires Wall Switch and Cover Plate ORIFICE Natural 105890 01 27224 REPLACEMENT PARTS A A B...

Page 27: ...PARTS Continued Front Bottom Left Right Bottom Front Used for See Thru Only GRATE 105889 01 11184 DOOR ASSEMBLY Tempered 106923 01 27200 LOUVER KIT Black 105904 01 01627 END LOUVER KIT Peninsula Only...

Page 28: ...l be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIE...

Reviews: