background image

17

106573

OWNER’S MANUAL

INSTALLATION

Continued

GAS LINE HOOK-UP

Figure 39 - Typical Exterior Wall Gas
Shutoff Installation

 WARNING: Gas line hookup

should be done by your gas sup-
plier or a qualified service person.

 WARNING: Before you pro-

ceed, make sure your gas supply
is OFF.

A equipment shutoff valve has been in-
cluded in the appliance’s gas supply system.
You may consider installing an extra gas
shutoff valve outside the appliance’s enclo-
sure (check with local codes) where it can be
accessed more conveniently with a key
through a wall as shown in Figure 39.

Key

Extension

Shutoff Valve

 CAUTION: Compounds used

on threaded joints of gas piping
shall be resistant to the action of
Liquefied Petroleum (LP or pro-
pane), and should be applied
lightly to ensure excess sealant
does not enter the gas line.

 CAUTION: Do not kink flex-

ible gas line.

Route a 1/2” NPT black iron gas line to-
wards the appliance coming in from the left.
It is recommended to route the pipe between
the stand of the firebox and the surround of
the fireplace (see Figure 40).

IMPORTANT:

 The appliance and its indi-

vidual shutoff valve must be disconnected
from the gas supply piping system during
any pressure testing of that system at test
pressures in excess of 1/2 psig. (3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its indi-
vidual equipment shutoff valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig. (3.5 kPa).

1.

Install a sediment trap between the in-
coming gas line and the gas control
valve (see Figure 40). The sediment
trap should extend down the center of
the pipe. Refer to your local codes.

2.

Prepare incoming gas line and check
with local codes regarding the use of
teflon tape. Complete your gas line in-
stallation by connecting incoming gas
line with flexible gas line. Secure
tightly with a wrench, but Do NOT
Overtighten.

OPTIONAL REMOTE
CONTROL INSTALLATION
(Model WRC)

Note:

 If using optional wireless hand-held

remote control, the wall switch must be in
the ON position to be operational. The re-
mote control then becomes the switching
mechanism for fireplace operation.

1.

The WRC model receiver does not re-
quire a battery. The receiver can be in-
stalled by first plugging the short ex-
tension cord into the fireplace junction
box. Then plug the receiver unit into
the extension cord. Finally plug the ig-
nition module plug into the receiver unit
(see Figure 37).

2.

Activate the remote handset battery by
removing the insulating tab on the back
of the handset (see Figure 38). The bat-
tery is included pre-installed.

3.

Once the battery is activated the unit is
ready to use.

Figure 37 - Installing the WRC Remote
Receiver

Junction
Box

Remote
Control
Receiver

Extension
Cord

Ignition
Module Plug

Figure 38 - Installing Battery into Back of
Handset

Pull to Remove
Insulation Tab

Battery Cover

12 Volt Battery

Back of Handset

Continued

Bac

k W

all

Of Appliance

Incoming 1/2"
Gas Line
Permitted by
Local Codes

Sediment Trap (Not Supplied)

Figure 40 - Sediment Trap

Summary of Contents for Vanguard EVDDVF36PN

Page 1: ...gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier SAVE...

Page 2: ...d Back of Surround Figure 2 EVDDVF36STN See Thru Dimensions Left Side Surround Right Side Surround Rating Plate Location Left Side Surround Right Side Surround GLOSSARY OF TERMS Chase A box like enclo...

Page 3: ...gas approved for use in this gas appliance NOTICE Check local building codes for area requirements be fore installing this appliance This appliance when installed must be elec trically grounded in ac...

Page 4: ...ock re quired air spaces with insula tion or any other material Do not obstruct the effective opening of the appliance with any type of facing material MANTEL CLEARANCES Woodwork such as wood trims ma...

Page 5: ...ting terminals into a wall or siding If installing on vinyl siding a vinyl sid ing standoff must be used see Figure 19 page 9 Install horizontal venting with a 1 4 rise for every 12 of run toward the...

Page 6: ...aved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 2...

Page 7: ...t is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical...

Page 8: ...the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide strai...

Page 9: ...of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained...

Page 10: ...al V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting FGFVK Vent Kit Shown Horizontal Termination Configurations Figures 21 through 23 show different con figurations...

Page 11: ...90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 4 max 6 min 8 max 7 min 10 max 8 min 15 max 20 max 20 max Figure 23 Horizontal Termination Configuration for Rigid Venting Using Two 90 Elbows w...

Page 12: ...ances air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do not pack air spaces with insulation Also note maxi mum vertical rise of the venting sys tem a...

Page 13: ...ort box vertically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corne...

Page 14: ...tion With No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Fi...

Page 15: ...shing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustabl...

Page 16: ...he blower system will not flow properly WARNING Disconnect all electrical power to the fireplace Be careful of burrs and sharp edges BLOWER SPEED CONTROL INSTALLATION 1 Place speed control switch asse...

Page 17: ...em at test pressures equal to or less than 1 2 psig 3 5 kPa 1 Install a sediment trap between the in coming gas line and the gas control valve see Figure 40 The sediment trap should extend down the ce...

Page 18: ...to prevent damage to glass or refractory 1 Remove top and bottom louvers by si multaneously pulling both top end spring latches towards the center of the applianceuntiltheyaredisengagedfrom locating...

Page 19: ...d during shipping and han dling If this is the case some minor adjust ments may be necessary and should be done by a qualified technician To access the elec trode the glass door must be opened The pro...

Page 20: ...ng ignition Young children should be carefully supervised when they are in the same room as the appliance WARNING Have a qualified agency periodically inspect the vent system at the start of each heat...

Page 21: ...tes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation in column one If you don t smell gas go to the next step 7 Turnequipments...

Page 22: ...iginalreplacementpart s call DESA International s Technical Ser vice Department at 1 800 323 5190 for re ferral information When calling DESA International have ready your name your address model and...

Page 23: ...Replace control valve see Replacement Parts page 27 5 Tighten wires or replace electrode 6 Check that the main power is on and that all wire connections are made correctly to the ignition module see W...

Page 24: ...oved from line Have gas line checked by local pro pane LP gas company 2 Clean burner or replace burner orifice 1 Adjust the log set so that the flame does not excessively impinge on it 2 Inspect the o...

Page 25: ...ss too loose and air tight gasket leaks in corners after usage 6 Improper vent cap installation 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Bu...

Page 26: ...overplate andmillivoltwires are supplied with the appliance If wires need replacing use proper gauge Millivolt Wires Wall Switch and Cover Plate ORIFICE Natural 105890 01 27224 REPLACEMENT PARTS A A B...

Page 27: ...PARTS Continued Front Bottom Left Right Bottom Front Used for See Thru Only GRATE 105889 01 11184 DOOR ASSEMBLY Tempered 106923 01 27200 LOUVER KIT Black 105904 01 01627 END LOUVER KIT Peninsula Only...

Page 28: ...l be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIE...

Reviews: