background image

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com

NOT A UPC

115043-01
Rev. C
06/05

115043 01

WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our 

standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY - VENTED GAS LOGS

DESA warrants this product to be free from defects in materials and components of the burner system for two 

(2) years and a lifetime on logs   from the date of first purchase, provided that the product has been properly 

installed, operated and maintained in accordance with all applicable instructions. To make a claim under this 

warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required 

to restore this log set to proper operating condition and an allowance for labor when provided by a DESA Au-

thorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or 

DESA who will provide original factory replacement parts. Failure to use original factory replacement parts 

voids this warranty. The log set MUST be installed by a qualified installer in accordance with all local codes 

and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts 

that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by 

improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to 

repairing a defective log set will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE 

OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED 

WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) 

YEARS ON burner system and a lifetime on logs FROM THE DATE OF FIRST PURCHASE; AND DESAʼS 

LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL 

NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL 

OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of 

incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation 

on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:

Summary of Contents for Comfort Glow BRENTWOOD LCF18

Page 1: ...nce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow th...

Page 2: ...ust be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactu...

Page 3: ...cals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep ue open when operating unit IMPORTANT Read this owner s manual carefully and completely b...

Page 4: ...h the Na tional Fuel Gas Code ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation 7 Do not run log set where ammable liquids or vapors are used or stored under dusty conditions 8 Do not...

Page 5: ...r this appliance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 INSTALLATION CAUTION Donotremovethe dataplatesattachedtotheburner...

Page 6: ...ht a tightly rolled newspaper on one end and place it at the inside front edge of the replace Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into...

Page 7: ...system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set contr...

Page 8: ...d see Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional...

Page 9: ...nifold and reaming the ports with a modi ed paper clip or other suitable tool 5 When nished testing turn the gas shutoff valve OFF to extinguish all ames ADDING PAN MATERIAL 1 Open the bag of ash bed...

Page 10: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department LIGHTING INSTRUCTIONS 1 STOP Read the safety informa...

Page 11: ...this log set for the rst time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not...

Page 12: ...ave your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com REPLACEMENT PARTS Note Use only original replacement parts This will...

Page 13: ...sets to produce moderate levels of carbon soot where ames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner ame...

Page 14: ...ROBLEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but ame goes out when control knob is released GA9050A Only Burner does not light after pilot i...

Page 15: ...ce person 1 Open ue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Page 16: ...www desatech com 115043 01C 16 ILLUSTRATED PARTS BREAKDOWN MODELS LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Page 17: ...nifold 1 6 901137 01 901137 02 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assy 1 8 101628 01 101628 01 Gas Line 10 Flex 1 9 901431 01 901431 01 Grate Steps 2 10 901246 01 901246 02 Log Grate...

Page 18: ...Y VALVE PILOT KIT GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown For decorative purposes on...

Page 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 20: ...his warranty The log set MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in ori...

Reviews: