UNPACKING

 CAUTION: Do not remove the 

data plates from the burner pan. 

The data plates contain impor-

tant product information.

1.  Remove logs, hearth kit, pan materials, and 

hardware from carton.

2.  Remove all protective packaging applied to 

logs and base for shipment.

3.  Check all items for any shipping damage. If 

damaged, promptly inform dealer where you 

bought the product.

OPTIONAL PRODUCT 

FEATURES

ON/OFF SAFETY VALVE/PILOT KIT 
AND PROPANE/LP CONVERSION

An optional valve/safety pilot kit with a piezo 

ignitor is available for this appliance. This system 

requires no matches, batteries, or other sources to 

light. You must use this optional system for LP 

conversion. See 

Accessories

, page 18.

REMOTE CONTROL READY 
(MILLIVOLT) SAFETY VALVE/PILOT 
KIT

An optional millivolt valve/safety pilot kit with a 

piezo ignitor is available for this appliance. This 

system requires no matches, batteries, or other 

sources to light. This system may be connected to a 

wall switch or hand-held wireless remote control. 

See 

Accessories

, page 18.

REMOTE CONTROL ACCESSORIES

There is an optional hand-held ON/OFF remote 

control that can be purchased separately for this log 

set. You must use the millivolt valve/safety pilot 

kit to use remote accessories with this appliance. 

See 

Accessories

, page 18.

A wall switch is also available for this appliance. 

You must use the millivolt valve/safety pilot kit 

to use the wall switch with this appliance. See 

Accessories

, page 18.

INSTALLATION

 CAUTION: Do not remove the 

data plates attached to the burner 

pan. The data plates contain im-

portant warranty information.

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo-

sote, ashes and loose paint by a 

qualified chimney cleaner. Creo-

sote will ignite if highly heated. 

A dirty chimney flue may create 

and  distribute  soot  within  the 

house. Inspect chimney flue for 

damage. If damaged, repair flue 

before operating appliance.

NOTICE:  Installation,  service, 

and repair of this appliance must 

be performed by a qualified in-

staller, service agency, company 

or gas supplier experienced with 

this type of gas appliance. Only 

factory authorized components 

listed in these instructions may 

be used in accordance with the 

manufacturer’s instructions and 

all  codes  and  requirements  of 

the  authority  having  jurisdic-

tion. Any  modifications  to  this 

kit,  or  use  of  unauthorized 

components or accessory items 

will  void  the  manufacturer’s 

warranty,  and  may  result  in  a 

hazardous condition.

FLUE OPENING SPECIFICATIONS

Note:

 This vented appliance must be installed only 

in a solid-fuel burning fireplace with a working flue 

and constructed of noncombustible material.
The charts in Figure 2, page 6 indicate technical 

information regarding the installation of your gas 

log set. Please make sure that all of the specifica-

tions shown are applicable before installation is 

attempted.

Summary of Contents for Comfort Glow BRENTWOOD LCF18

Page 1: ...nce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow th...

Page 2: ...ust be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactu...

Page 3: ...cals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep ue open when operating unit IMPORTANT Read this owner s manual carefully and completely b...

Page 4: ...h the Na tional Fuel Gas Code ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation 7 Do not run log set where ammable liquids or vapors are used or stored under dusty conditions 8 Do not...

Page 5: ...r this appliance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 INSTALLATION CAUTION Donotremovethe dataplatesattachedtotheburner...

Page 6: ...ht a tightly rolled newspaper on one end and place it at the inside front edge of the replace Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into...

Page 7: ...system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set contr...

Page 8: ...d see Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional...

Page 9: ...nifold and reaming the ports with a modi ed paper clip or other suitable tool 5 When nished testing turn the gas shutoff valve OFF to extinguish all ames ADDING PAN MATERIAL 1 Open the bag of ash bed...

Page 10: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department LIGHTING INSTRUCTIONS 1 STOP Read the safety informa...

Page 11: ...this log set for the rst time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not...

Page 12: ...ave your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com REPLACEMENT PARTS Note Use only original replacement parts This will...

Page 13: ...sets to produce moderate levels of carbon soot where ames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner ame...

Page 14: ...ROBLEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but ame goes out when control knob is released GA9050A Only Burner does not light after pilot i...

Page 15: ...ce person 1 Open ue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Page 16: ...www desatech com 115043 01C 16 ILLUSTRATED PARTS BREAKDOWN MODELS LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Page 17: ...nifold 1 6 901137 01 901137 02 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assy 1 8 101628 01 101628 01 Gas Line 10 Flex 1 9 901431 01 901431 01 Grate Steps 2 10 901246 01 901246 02 Log Grate...

Page 18: ...Y VALVE PILOT KIT GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown For decorative purposes on...

Page 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 20: ...his warranty The log set MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in ori...

Reviews: