background image

www.desatech.com

115043-01C

11

Shutting Off Appliance

Turn gas shutoff valve clockwise 

 to the 

OFF position.

CURING 

LOGS

During the 2-3 hour appliance break-in period, 

you may detect an odor from the appliance 

as the various paints and compounds used in 

the manufacturing of this log set cure. This is 

a normal and temporary situation that is not 

cause for alarm. However, you may want to 

provide extra ventilation to the room during 

this time.

To ensure proper curing of the logs:

•  Ignite  a  2"  flame  and  maintain  it  for  1 

hour.

•  Burn the logs in consecutive 1 hour periods 

raising the flame an additional 2" to full 

flame height for a total of three hours.

OPERATING 

INSTRUCTIONS  

FOR GA9050A

Note:

  Operation  instructions  for  GA9150A 

Remote Ready Valve/Pilot Kit will be included 

with the kit.

1.  STOP! Read the safety information, page 10.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Press in and turn control knob clockwise  

 to the OFF position.

4.  Wait five (5) minutes to clear out any gas. 

Then smell for gas around log set and near 

floor. If you smell gas, STOP! Refer to the 

National  Fuel  Gas  Codes, ANSI  Z233.1/

NFPA 54, Section 5.3, Air for Combustion 

and Ventilation.

 If you donʼt smell gas, go 

to the next step.

5.   Turn control knob counterclockwise 

  

to the PILOT position and press in. Keep 

control knob pressed in for five (5) seconds.

 

Note:

 You may be running this log set for 

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be 

pressed in for 30 seconds. This will allow 

air to bleed from the gas system.

• If control knob does not pop up when 

released, contact a qualified service person 

or gas supplier for repairs.

OPERATING APPLIANCE

Continued

6.  With control knob pressed in, push down 

and release ignitor button. This will light 

pilot. The pilot is attached to the rear of 

the front burner. If needed, keep pressing 

ignitor button until pilot lights.

 

Note:

 If pilot does not stay lit, contact a 

qualified service person or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. 

7.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

 

Note:

  If  pilot  goes  out,  repeat  steps  3 

through 7.

8.  Turn control knob counterclockwise  

  

to 

the

 ON position. Burner should light. If 

burner does not light, call a qualified service 

person.

Ignitor

Control Knob

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO 

TURN OFF 

PULL PUSH 

TO LIGHT

ON

ON

FROM "PILOT" POSITION

SLIGHT

 PUSH 

T

TURN OFF 

PULL

 PUSH 

T

O LIGHT

FROM "PILOT" POSITION

SLIGHT

 PUSH 

T

TURN OFF 

PULL

 PUSH 

T

O LIGHT

ON

OFF

On

Off

OFF

OFF

Figure 12 - Ignitor and Control Knob

Figure 13 - Thermocouple and Pilot

Pilot 
Burner

Thermocouple

TO TURN OFF GAS 

TO APPLIANCE

Shutting Off Appliance

1.  Turn control knob clockwise 

 to the 

PILOT position.

2.  Press in and turn control clockwise 

 

to the OFF position. 

Shutting Off Burner Only (pilot stays lit)

Turn  control  knob  clockwise   

 to  the 

PILOT position.

Summary of Contents for Comfort Glow BRENTWOOD LCF18

Page 1: ...nce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow th...

Page 2: ...ust be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactu...

Page 3: ...cals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep ue open when operating unit IMPORTANT Read this owner s manual carefully and completely b...

Page 4: ...h the Na tional Fuel Gas Code ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation 7 Do not run log set where ammable liquids or vapors are used or stored under dusty conditions 8 Do not...

Page 5: ...r this appliance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 INSTALLATION CAUTION Donotremovethe dataplatesattachedtotheburner...

Page 6: ...ht a tightly rolled newspaper on one end and place it at the inside front edge of the replace Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into...

Page 7: ...system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set contr...

Page 8: ...d see Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional...

Page 9: ...nifold and reaming the ports with a modi ed paper clip or other suitable tool 5 When nished testing turn the gas shutoff valve OFF to extinguish all ames ADDING PAN MATERIAL 1 Open the bag of ash bed...

Page 10: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department LIGHTING INSTRUCTIONS 1 STOP Read the safety informa...

Page 11: ...this log set for the rst time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not...

Page 12: ...ave your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com REPLACEMENT PARTS Note Use only original replacement parts This will...

Page 13: ...sets to produce moderate levels of carbon soot where ames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner ame...

Page 14: ...ROBLEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but ame goes out when control knob is released GA9050A Only Burner does not light after pilot i...

Page 15: ...ce person 1 Open ue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Page 16: ...www desatech com 115043 01C 16 ILLUSTRATED PARTS BREAKDOWN MODELS LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Page 17: ...nifold 1 6 901137 01 901137 02 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assy 1 8 101628 01 101628 01 Gas Line 10 Flex 1 9 901431 01 901431 01 Grate Steps 2 10 901246 01 901246 02 Log Grate...

Page 18: ...Y VALVE PILOT KIT GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown For decorative purposes on...

Page 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 20: ...his warranty The log set MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in ori...

Reviews: