background image

www.desatech.com

115043-01C

4

 1.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use 

any phone in your building

• immediately call your gas supplier from a 

neighborʼs phone. Follow the gas supplierʼs 

instructions

• if you cannot reach your gas supplier, call 

the fire department

2.  Never install the log set

• in a recreational vehicle

• where curtains, furniture, clothing, or other 

flammable objects are less than 42 inches 

from the front, top, or sides of the log set

• in high traffic areas

• in windy or drafty areas

3.  Before installing in a solid fuel burning fireplace, 

the chimney flue and firebox must be cleaned of 

soot, creosote, ashes and loose paint by a qualified 

chimney cleaner. Creosote will ignite if highly 

heated. Inspect chimney flue for damage. If dam-

aged, repair flue before operating appliance.

4.  This log set is designed to be smokeless. If 

logs ever appear to smoke, turn off appliance 

and  call  a  qualified  service  person. 

Note:

 

During initial operation, slight smoking could 

occur due to log curing and the burning of 

manufacturing residues. You may wish to add 

more ventilation by opening a window.

5.  To  reduce  the  creation  of  soot,  follow  the 

instructions in 

Cleaning and Maintenance

page 12.

6.  The installation and provisions for combustion 

and ventilation air must conform with the 

Na-

tional Fuel Gas Code, ANSI Z233.1/NFPA 54, 

Section 5.3, Air for Combustion and Ventilation

.

7.  Do not run log set

• where flammable liquids or vapors are used 

or stored

• under dusty conditions

8.  Do not burn solid fuel in the fireplace after 

installing the log set. Do not use this log set 

to cook food or burn paper or other objects.

9.  Do not use appliance if any part has been 

exposed to or under water. Immediately call 

a qualified service technician to inspect the 

room appliance and to replace any part of 

the  control  system  (if  using  GA9050A  or 

GA9150A) and any gas control which has 

been under water. 

SAFETY INFORMATION

Continued

10.  To help prevent breakage, new logs must be 

broken-in (see 

Curing Logs

 page 11).

11.  Turn log set off and let cool before servicing, 

installing, or repairing. Only a qualified ser-

vice person should install, service, or repair 

log set. 

12.  Provide  adequate  clearances  around  air 

openings.

PRODUCT 

IDENTIFICATION

Figure 1 - Product Identification (Dual 

Burner Shown)

Hearth Kit Model ____________________
Serial Number ______________________
Log Set Model ______________________

Grate

Burner 
Pan

Burner 
Manifold

Burner Inlet 
Fitting

Burner 
Clamp

Grate 
Steps

LOCAL CODES

Install and use log set with care. Follow all local 

codes. In the absence of local codes, use the lat-

est edition of the 

National Fuel Gas Code ANSI 

Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Summary of Contents for Comfort Glow BRENTWOOD LCF18

Page 1: ...nce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow th...

Page 2: ...ust be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactu...

Page 3: ...cals known to the State of California to cause cancer or birth defects or other reproductive harm WARNING Keep ue open when operating unit IMPORTANT Read this owner s manual carefully and completely b...

Page 4: ...h the Na tional Fuel Gas Code ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation 7 Do not run log set where ammable liquids or vapors are used or stored under dusty conditions 8 Do not...

Page 5: ...r this appliance You must use the millivolt valve safety pilot kit to use the wall switch with this appliance See Accessories page 18 INSTALLATION CAUTION Donotremovethe dataplatesattachedtotheburner...

Page 6: ...ht a tightly rolled newspaper on one end and place it at the inside front edge of the replace Observe the smoke and be sure the vent is properly drawing it up the chimney If the smoke spills out into...

Page 7: ...system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze Asediment trap traps moisture and contaminants This keeps them from going into log set contr...

Page 8: ...d see Figure 6 Tighten using a wrench 6 Using burner clamp screw and nut provided assemble clamp to pan U style and triple burners only This will hold the burner mani fold in place 7 If using optional...

Page 9: ...nifold and reaming the ports with a modi ed paper clip or other suitable tool 5 When nished testing turn the gas shutoff valve OFF to extinguish all ames ADDING PAN MATERIAL 1 Open the bag of ash bed...

Page 10: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department LIGHTING INSTRUCTIONS 1 STOP Read the safety informa...

Page 11: ...this log set for the rst time after hooking up to gas sup ply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not...

Page 12: ...ave your model and serial numbers of your appliance ready You can also visit DESA s technical services web site at www desatech com REPLACEMENT PARTS Note Use only original replacement parts This will...

Page 13: ...sets to produce moderate levels of carbon soot where ames contact the logs Burner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise Burner ame...

Page 14: ...ROBLEM When ignitor button is pressed there is spark at pilot but no igni tion GA9050A Only Pilot lights but ame goes out when control knob is released GA9050A Only Burner does not light after pilot i...

Page 15: ...ce person 1 Open ue to maximum Stop using odor causing products while log set is running 2 Locate and correct all leaks see Checking Gas Connec tions page 7 1 Locate and correct all leaks see Checking...

Page 16: ...www desatech com 115043 01C 16 ILLUSTRATED PARTS BREAKDOWN MODELS LCF18 AND LCF24 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14 20 15 16 19 18 17...

Page 17: ...nifold 1 6 901137 01 901137 02 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assy 1 8 101628 01 101628 01 Gas Line 10 Flex 1 9 901431 01 901431 01 Grate Steps 2 10 901246 01 901246 02 Log Grate...

Page 18: ...Y VALVE PILOT KIT GA9150A Not Shown For all models Required for remote control operation Contains components for propane LP conversion INDIVIDUAL ROUND LOG GA9450A Not Shown For decorative purposes on...

Page 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 20: ...his warranty The log set MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in ori...

Reviews: