background image

Owner’s Manual

Model 
DF1870L

7213430100R00

IMPORTANT SAFETY INFORMATION: 

Always read this manual first 

before attempting to install or use this fireplace. For your safety, always 

comply with all warnings and safety instructions contained in this manual 

to prevent personal injury or property damage.

 

 

To view the full line of Dimplex products, please visit

 

www.dimplex.com

Summary of Contents for DF1870L

Page 1: ...d this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage To view the full line of Dimplex products please visit www dimplex com ...

Page 2: ...to emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death Welcome Congratulations 3 IMPORTANT INSTRUCTIONS 4 Fireplace Installation 6 Operation 7 Maintenance 9 Warranty 10 Replacement Parts 12 ...

Page 3: ... void the warranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace Model Number Serial Number NO NEED TO RETURN TO THE STORE Questions with operation or assembly Require Parts Information Product Under Manufacturer s Warranty Contact us at www dimplex com customer_support For Trouble...

Page 4: ...nd have the heater inspected by a reputable electrician before reus ing Do not operate any unit with a damaged cord or plug or if the heater has malfunctioned or if the electric fireplace has been dropped or damaged in any man ner contact Dimplex Technical Service at 1 888 346 7539 Do not use outdoors Never locate heater where it may fall into a bathtub or other water container Do not run the cord...

Page 5: ...an extension cord or relocatable power tap outlet power strip Do not strike the fireplace glass Always use a certified electri cian should new circuits or outlets be required Always use properly grounded fused and polarized outlets Disconnect all power supply before performing any cleaning maintenance or relocation of the unit When transporting or stor ing the unit and cord keep in a dry place fre...

Page 6: ...long 3 wire cord exiting out the back of the fireplace insert Plan the installation to avoid the use of an extension cord CAUTION High temperature risk of fire keep electrical cords drapery furnishings and other combustibles at least 3 ft 0 9 m from the front of the heater WARNING Electrical outlet wir ing must comply with local build ing codes and other applicable regulations to reduce the risk o...

Page 7: ...ase flame brightness Press to decrease flame brightness Figure 1 C B A D Heater Control Low heat 500 watts High heat 1000 watts The touchpad control for the heat er must be touched 2 times to achieve high heat E Heater Timer Allows you to leave your heater on while you sleep with an auto matic timer for shut off You can set your heater to be on for 1 2 hour increments starting at a 1 2 hour up to ...

Page 8: ...e heater may emit a slight harmless odor when first used This odor is a normal condi tion caused by initial heating of internal heater parts and will not occur again Remote Controls Power ON OFF Power to the unit Heater Timer Allows you to leave your heater on while you sleep with an automatic timer for shut off You can set your heater to be on for 1 2 hour increments starting at a 1 2 hour up to ...

Page 9: ...installation handling etc the front glass panel may collect dust particles these can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the front glass panel can be cleaned with a damp cloth The front glass panel should be completely dried with a lint free cloth to prevent water spots To prevent scratching do not use abrasive cleaners or spray liquids on the...

Page 10: ...ted and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in mate rial and workmanship for a period of 12 months from the date of the first purchase of such product The limited 12 month warranty period also applies to any implied warranties that may exist under applicable law Some jurisdic tions do not allow limitation...

Page 11: ...ts Such costs shall be the purchaser s responsibil ity What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CON TRACT IN TORT OR ON ANY OTHER BASIS FOR ANY INDIRECT SPECIAL PUNITIVE EXEMPLARY CONSEQUEN TIAL OR INCIDENTAL LOSS COST OR DAMAGE ARISING OUT OF OR...

Page 12: ...t 9600860300RP Switchboard 9600860400RP Cord Set 9600860500RP Front Glass 9600860600RP Remote Control 9600860700RP Remote Receiver 9600860800RP IR Sensor 9600860900RP 2013 Dimplex North America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 Replacement Parts ...