background image

     
 
 
 
 
 
 
 
                                           

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
DESA INTERNATIONAL 

2701 INDUSTRIAL DRIVE 

 

 

 

 

 

 

 

                                P/N 108771-01 

P.O. BOX 90024  

 

 

 

 

 

 

 

 

                                      

REV D

 

BOWLING GREEN, KY 42101-9004 

 

 

 

 

 

 

                                         

6/02

 

www.desatech.com

 

SAVE THIS BOOK 

This book is valuable.  In addition to instructing you on
how to install and maintain your appliance, it also
contains information that will enable you to obtain
replacement parts or accessory items when needed.
Keep it with your other important papers. 

This fireplace is approved for use as a wood burning fireplace or for
use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA
2-72 standards or for use with a vent-free gas log heater approved to
ANS Z21.11.2 standard.  A DESA hood must be installed when
using a vent-free gas log heater (see Accessories, p. 12). 

WARNING:  Always leave glass doors fully opened or fully closed when operating this fireplace. 

C36EMW 

36” Circulating Firebox 

Includes: Manual Variable Control Fan System, Combustion 

Air Kit and Bi-Fold Doors with Brushed Brass Finish 

 

INSTALLATION INSTRUCTIONS 

This firebox meets the construction and safety standards of H.U.D. for
application in mobile homes when installed according to these instructions. 

ALL DIMENSIONS IN THIS MANUAL ARE IN 
INCHES UNLESS OTHERWISE SPECIFIED

 

Summary of Contents for C36EMW

Page 1: ...proved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see A...

Page 2: ...ION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE PG 4 5 9 FIRESTOP THIMBLE AND SPACERS PG 5 6 10 FLASHING AND TERMINATION PG 7 11 FINISHING YOUR FIREPLACE PG 8 12 MANTEL PG 8 13 GLASS DOORS PG 8 14 GAS...

Page 3: ...lace to the flue gas outlet of the termination is 11 5 feet for straight flue or a flue with one elbow set The maximum distance between elbows is 2 feet For systems with 2 elbow sets minimum height is...

Page 4: ...N A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace...

Page 5: ...gh the strain relief opening and electrical cover plate and make all the necessary connections iv Slide all wiring connections in the electrical housing as shown in figure 6b v Secure the electrical c...

Page 6: ...c space of a manufactured home To install the thimble assembly determine the distance between the ceiling joist and the roof framing Attach the adjustable thimble to the firestop spacer so that the as...

Page 7: ...n in figure 13 PENETRATING THE ROOF To maintain a 1 inch clearance to the pipe on a roof with a pitch a rectangular opening must be cut STEP 1 Determine the center point through which the pipe will pe...

Page 8: ...ly waterproof caulk around the perimeter of the collar to provide a proper seal Note Storm collar is required but can be installed after the home is sited TERMINATIONS SPARK ARRESTOR The fireplace sys...

Page 9: ...A mantel may be installed if desired see figure 20 Woodwork such as wood trims mantels or any other combustible material projecting from the front face must not be placed within 9 inches of the firep...

Page 10: ...r Use only a inch black iron pipe and appropriate fittings When installing a gas line a shut off valve designed for installation outside the appliance is recommended STEP 1 To install remove the knock...

Page 11: ...re 25 Pulling the handle out will free the outside air door to open Pushing the handle in will lock the door close FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER T...

Page 12: ...11 For more information visit www desatech com ILLUSTRATED PARTS...

Page 13: ...ONT 1 50 16502 BAG POLY 1 16 106683 01 LEG FIREBOX SUPPORT 2 51 16901 STRAPPING 7 16 10 5 17 56090 COLEMAN DECAL 1 52 20023 COLLAR STARTER 1 18 106687 01 COLLAR DAMPER CAN 1 53 20027 RETAINER REFRACTO...

Page 14: ...24 8DM 24 Double Wall Pipe 1 0 18 8DM 18 Double Wall Pipe 0 2 FST A Adjustable Firestop Thimble 1 1 V6F 8DM Roof Flashing 1 1 VSC1 8DM Storm Collar 1 1 RTL 8DM Round Cap Termination 1 1 VENT KITS USE...

Page 15: ...DM 36 8DM DOUBLE WALL PIPE 36 SECTION 9736A1236 36 8DM 48 8DM DOUBLE WALL PIPE 48 SECTION 9736A1248 48 8DM V6F 8DM ROOF FLASHING 0 6 12 PITCH 9736 5241 V6F 8DM V12F 8DM ROOF FLASHING 6 12 12 12 PITCH...

Reviews: