ASSEMBLY AND INSTALLATION OF THE DOUBLE 

WALL CHIMNEY SYSTEM 

Each double wall chimney section is consist of a galvanized 
outer pipe, a stainless steel inner flue pipe and a wire spacer.  
The pipe sections must be assembled independently as the 
chimney is installed.  When connecting chimney directly to 
the fireplace, the inner flue pipe section must be installed first 
with the lanced side up.  The outer pipe section can then be 
installed over the flue pipe section with the hemmed end up.  
Press down on each pipe section until the lances securely 
engage the hem on the fireplace starter.  The wire will assure 
the proper spacing between the inner and outer pipe sections. 
 
 
 
 
 
 
 
Continue to assemble chimney sections as outlined above, 
making sure that both the inner and outer pipe sections are 
locked together.  When installing double wall “snap lock” 
chimney together, it is important to assure the joint between 
the chimney sections is locked.  Check by pulling chimney 
upward after locking.  The chimney will not come apart if 
properly locked.  It is not necessary to add screws to keep the 
chimney together (exception – see page 6 figure 12). 
 

ADJUSTABLE FIRESTOP THIMBLE (FST-A): 
 

The Adjustable Firestop Thimble Assembly (FST-A) is used 
to provide the necessary air space and clearance between the 
chimney pipe and the insulation in the attic space of a 
manufactured home. 
 
To install the thimble assembly, determine the distance 
between the ceiling joist and the roof framing.  Attach the 
adjustable thimble to the firestop spacer so that the assembly 
will cover the distance.  The adjustable thimble should be even 
with or above the roofline (see thimble extensions on page 12 
if a longer thimble is needed).  Sheet metal screws or staples 
may be used to attach the thimble to the firestop spacer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

An opening large enough to allow the insertion of the firestop 
thimble assembly will be required in the ceiling.  Attach the 
firestop/thimble assembly to the ceiling/ceiling joist using 
screws or staples as shown in figure 8.  A minimum of 8 
screws or staples should be used. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The firestop thimble assembly should also be used where there 
is a cathedral ceiling, insulation barrier and roof, all in one 
assembly in a manufactured home.  The FST-A Thimble can 
be used in any one of three common ceiling pitches: flat, 
12”/96”, and 30”/144”. 
 
An opening big enough to allow the insertion of the firestop 
thimble assembly will be required.  This opening depends on 
the pitch of your ceiling.  If your ceiling is a flat or 12”/96” 
pitch, you must use the adapter plate provided to seal 
unwanted openings since the opening in the firestop is an 
ellipse.  For 30”/144” pitch, discard the adapter. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 8            FIRESTOP THIMBLE 

Figure 9    FIRESTOP THIMBLE ASSEMBLY 

Figure 10            FIRESTOP THIMBLE 

WARNING: The opening in the collar around the

chimney at the top of the fireplace must not be
obstructed.  Never use blown insulation to fill the
chimney enclosure. 

Summary of Contents for C36EMW

Page 1: ...proved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see A...

Page 2: ...ION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE PG 4 5 9 FIRESTOP THIMBLE AND SPACERS PG 5 6 10 FLASHING AND TERMINATION PG 7 11 FINISHING YOUR FIREPLACE PG 8 12 MANTEL PG 8 13 GLASS DOORS PG 8 14 GAS...

Page 3: ...lace to the flue gas outlet of the termination is 11 5 feet for straight flue or a flue with one elbow set The maximum distance between elbows is 2 feet For systems with 2 elbow sets minimum height is...

Page 4: ...N A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace...

Page 5: ...gh the strain relief opening and electrical cover plate and make all the necessary connections iv Slide all wiring connections in the electrical housing as shown in figure 6b v Secure the electrical c...

Page 6: ...c space of a manufactured home To install the thimble assembly determine the distance between the ceiling joist and the roof framing Attach the adjustable thimble to the firestop spacer so that the as...

Page 7: ...n in figure 13 PENETRATING THE ROOF To maintain a 1 inch clearance to the pipe on a roof with a pitch a rectangular opening must be cut STEP 1 Determine the center point through which the pipe will pe...

Page 8: ...ly waterproof caulk around the perimeter of the collar to provide a proper seal Note Storm collar is required but can be installed after the home is sited TERMINATIONS SPARK ARRESTOR The fireplace sys...

Page 9: ...A mantel may be installed if desired see figure 20 Woodwork such as wood trims mantels or any other combustible material projecting from the front face must not be placed within 9 inches of the firep...

Page 10: ...r Use only a inch black iron pipe and appropriate fittings When installing a gas line a shut off valve designed for installation outside the appliance is recommended STEP 1 To install remove the knock...

Page 11: ...re 25 Pulling the handle out will free the outside air door to open Pushing the handle in will lock the door close FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER T...

Page 12: ...11 For more information visit www desatech com ILLUSTRATED PARTS...

Page 13: ...ONT 1 50 16502 BAG POLY 1 16 106683 01 LEG FIREBOX SUPPORT 2 51 16901 STRAPPING 7 16 10 5 17 56090 COLEMAN DECAL 1 52 20023 COLLAR STARTER 1 18 106687 01 COLLAR DAMPER CAN 1 53 20027 RETAINER REFRACTO...

Page 14: ...24 8DM 24 Double Wall Pipe 1 0 18 8DM 18 Double Wall Pipe 0 2 FST A Adjustable Firestop Thimble 1 1 V6F 8DM Roof Flashing 1 1 VSC1 8DM Storm Collar 1 1 RTL 8DM Round Cap Termination 1 1 VENT KITS USE...

Page 15: ...DM 36 8DM DOUBLE WALL PIPE 36 SECTION 9736A1236 36 8DM 48 8DM DOUBLE WALL PIPE 48 SECTION 9736A1248 48 8DM V6F 8DM ROOF FLASHING 0 6 12 PITCH 9736 5241 V6F 8DM V12F 8DM ROOF FLASHING 6 12 12 12 PITCH...

Reviews: