OUTSIDE AIR KIT (MODEL AK-6) 

The installation of an outside air kit should be performed 
during the rough framing of the fireplace due to the nature of 
its location.  Outside combustion air is accessed through the 
mobile home floor (Refer to AK-6 Installation Instructions for 
details).  In some instances, a wall installation is required (see 
Figure 5).  Note: An AK-6WAI Air Kit must be ordered when 
a sidewall installation is required (see accessories on page 12). 
See page 10, figure 25 for instructions on how to operate the 
air kit. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FAN KIT ASSEMBLY (BK3) 

A fan kit assembly is preinstalled in this fireplace.  Use of 
blowers or fans other than manufactured by DESA voids the 
warranty.  The fan is operated by pressing the rocker switch 
located at the lower right hand corner of the fireplace face. 
Fan kit electrical connections are made through the electrical 
cover plate located on the side of the fireplace as shown in 
figure 6a. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

FAN KIT WIRING INSTRUCTIONS 

i. 

Loosen the strain relief by turning the plastic screw 
counterclockwise. 

ii. 

Remove electrical cover plate (with strain relief) 
from the fireplace by removing the two sheet metal 
screws as shown in figure 6a. 

iii. 

Slide power source wiring through the strain relief 
opening and electrical cover plate and make all the 
necessary connections. 

iv. 

Slide all wiring connections in the electrical housing 
as shown in figure 6b. 

v. 

Secure the electrical cover plate with screws 
previously removed.  

vi. 

Tighten strain relief plastic screw. 

NOTE: Electrical housing and cover plate have sharp edges, 
wear protective gloves. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CHIMNEY PIPE 

The DESA chimney system consists of 12, 18, 24, 36 and 48 
inch, snap-lock double-wall pipe segments, planned for 
maximum adaptability to individual site requirements.  Actual 
lengths gained after fitting overlaps must be taken into 
consideration (lineal gain) and are given in the lineal gain 
chart (see figure 7). 
There are two vent kits available, which have been specially 
designed for common installations in manufactured (mobile 
homes): MW8K (8’ Vent Kit) and MW9K (9’ Vent Kit).  The 
contents of these kits are listed under accessories on page 12.  
Most chimney systems for manufactured houses require a 
standard straight installation as described in this section.  If an 
uncommon offset installation is required, see page 10. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Important: If the height of the chimney assembly exceeds 
requirements for transportation of the home, the chimney 
installation may be completed after the home is sited. 
Note: the termination must always be installed after the home 
is sited. 

 

Figure 5                 OUTSIDE AIR KIT 

Figure 6b        ELECTRICAL HOUSING

Figure 6a      FAN SWITCH AND STRAIN RELIEF 

Figure 7                         LINEAL GAIN

Summary of Contents for C36EMW

Page 1: ...proved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see A...

Page 2: ...ION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE PG 4 5 9 FIRESTOP THIMBLE AND SPACERS PG 5 6 10 FLASHING AND TERMINATION PG 7 11 FINISHING YOUR FIREPLACE PG 8 12 MANTEL PG 8 13 GLASS DOORS PG 8 14 GAS...

Page 3: ...lace to the flue gas outlet of the termination is 11 5 feet for straight flue or a flue with one elbow set The maximum distance between elbows is 2 feet For systems with 2 elbow sets minimum height is...

Page 4: ...N A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace...

Page 5: ...gh the strain relief opening and electrical cover plate and make all the necessary connections iv Slide all wiring connections in the electrical housing as shown in figure 6b v Secure the electrical c...

Page 6: ...c space of a manufactured home To install the thimble assembly determine the distance between the ceiling joist and the roof framing Attach the adjustable thimble to the firestop spacer so that the as...

Page 7: ...n in figure 13 PENETRATING THE ROOF To maintain a 1 inch clearance to the pipe on a roof with a pitch a rectangular opening must be cut STEP 1 Determine the center point through which the pipe will pe...

Page 8: ...ly waterproof caulk around the perimeter of the collar to provide a proper seal Note Storm collar is required but can be installed after the home is sited TERMINATIONS SPARK ARRESTOR The fireplace sys...

Page 9: ...A mantel may be installed if desired see figure 20 Woodwork such as wood trims mantels or any other combustible material projecting from the front face must not be placed within 9 inches of the firep...

Page 10: ...r Use only a inch black iron pipe and appropriate fittings When installing a gas line a shut off valve designed for installation outside the appliance is recommended STEP 1 To install remove the knock...

Page 11: ...re 25 Pulling the handle out will free the outside air door to open Pushing the handle in will lock the door close FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER T...

Page 12: ...11 For more information visit www desatech com ILLUSTRATED PARTS...

Page 13: ...ONT 1 50 16502 BAG POLY 1 16 106683 01 LEG FIREBOX SUPPORT 2 51 16901 STRAPPING 7 16 10 5 17 56090 COLEMAN DECAL 1 52 20023 COLLAR STARTER 1 18 106687 01 COLLAR DAMPER CAN 1 53 20027 RETAINER REFRACTO...

Page 14: ...24 8DM 24 Double Wall Pipe 1 0 18 8DM 18 Double Wall Pipe 0 2 FST A Adjustable Firestop Thimble 1 1 V6F 8DM Roof Flashing 1 1 VSC1 8DM Storm Collar 1 1 RTL 8DM Round Cap Termination 1 1 VENT KITS USE...

Page 15: ...DM 36 8DM DOUBLE WALL PIPE 36 SECTION 9736A1236 36 8DM 48 8DM DOUBLE WALL PIPE 48 SECTION 9736A1248 48 8DM V6F 8DM ROOF FLASHING 0 6 12 PITCH 9736 5241 V6F 8DM V12F 8DM ROOF FLASHING 6 12 12 12 PITCH...

Reviews: