background image

Installation Instructions and Homeowner s Manual

,

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

WARNING! IF INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR 

EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS

 IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

ELECTRIC FIREPLACE 

 

MODEL NO. OL-L6G 

Summary of Contents for OL-L6G

Page 1: ...RNING IF INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AFIRE OR EXPLOSION MAYRESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY DO NOT STO RE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR AN Y OTHER APPLIANCE ELECTRIC FIREPLACE MODEL NO OL L6G ...

Page 2: ... guarantee Thank you and congratulations on your purchase of a OLMO fireplace 1 Installation Instructions Locating Your Fireplace Hearth Electrical Specifications Electrical Connection Service Instructions Maintenance of Motors Replacing the Light Bulbs Operating Instruction Manual Operation Remote Control Operation Guarantee Assembling Instruction 2 3 3 3 5 6 7 7 4 4 Glass Information 4 Measure 3...

Page 3: ...Measure 2 Power Flame switch 0 9kw output 1 8kw output Cold air enter Hot air extra 700mm 27 56 810mm 31 89 250mm 711mm 850mm 895mm 48mm 9 84 35 23 27 99 33 46 1 89 20mm 0 79 ...

Page 4: ...grounded in accordance with local codes 14 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock fire or damage the appliance 15 To prevent possible fire do not block air intakes or exhaust in any manner Do not use on soft surfaces like a bed where openings may become blocked Voltage Total Amps Total Watts Heater Ratings 220VAC 50Hz ...

Page 5: ...ician to inspect the fireplace and replace any part of the electrical system WARNING This fireplace comes with an ES In case the fireplace is not operating disconnect the power and reset the ES If the fireplace is still not operating immediately call a qualified service technician to inspect the fireplace Service Instructions WARNING Disconnect power before attempting any maintenance or cleaning t...

Page 6: ...o sides of the frame and pull the frame off See fig 1 4 Take off the glass carefully see fig 2 5 Remove the screw securing the ember bed positi on in the side of the ember see fig 3 6 Lift ember bed and take it off see fig 4 7 Replace the bulb see fig 5 8 Reinstall the ember bed the glass and the frame WARNING Do not exceed 60 watts per bulb for lights beneath the ember bed Use of higher rated bul...

Page 7: ...ing Loom Wire Terminal Block Cable Clamp Remote Item 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Part Description 6 10 10 26 26 18 18 20 20 25 25 01 01 02 02 03 03 04 04 05 05 06 06 08 08 09 09 21 21 15 15 23 23 22 22 17 17 16 16 12 12 14 14 24 24 13 13 19 19 11 11 27 27 12 12 07 07 Part Part 3004126 3004134 3004144 1002150 3004277 1002108 3004167 3004300 1002011 1002260 5006310 1002111 2 1002060 30...

Page 8: ...elvemonth guarantee does not apply to 1 Damage or inferior workmanship practices while the product is being installed 2 Damage caused by the misuse of the product or where normal standards of care and use have not been complied with the instruction 3 Damage or defects due to misuse accident or unauthorized alterations During the twelve month after the product has been supplied the guarantee covers...