                                                                                                         - 7 -                                          

For more information, visit www.desatech.com

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

FLASHING INSTALLATION (V6F-8DM or V12F-8DM) 

Determine the flashing to be used with the roof opening chart.   
Slide flashing over pipe until base is flat against roof.  Replace 
as many shingles as needed to cover exposed area and flashing 
base.  Secure in position by nailing through shingles (see 
figure 15). 
DO NOT NAIL THROUGH FLASHING CONE. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INSTALLING FLASHING ON A METAL ROOF 

When installing the flashing on a metal roof, it is required that 
putty tape be used between the flashing and the roof.  The 
flashing must be secured to the roof using #8 x ¾” screws and 
then sealed with roof coating to prevent leakage through the 
screw holes.  A roof coating must also be applied around the 
perimeter of the flashing to provide a proper seal. 
 

STORM COLLAR INSTALLATION  (SC1) 
 

Place storm collar over pipe and slide down until it is snug 
against the open edge of the flashing (see figure 16).  Apply 
waterproof caulk around the perimeter of the collar to provide 
a proper seal. 
 
 

Note: Storm collar is required but can be installed after the 
home is sited. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
TERMINATIONS / SPARK ARRESTOR 
 

The fireplace system must be terminated with the listed round 
top or chase terminations.  In any case, refer to the installation 
instructions supplied with the termination.  The terminations 
approved for this fireplace are the RTL-8DM, which can be 
use for flashing or chase and the ETL-8DM, for chase style 
termination only. Figure 17 shows an RTL-8DM round top 
termination. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
NOTE: 

In the rare instance there is a problem with the side 

driven rain or wind or the chimney is not drafting properly, an 
ADS-8DM Anti Draft Shield can be used with round 
terminations.

 

 

 

 

 

Figure 14          ROOF OPENING CHART 

PITCH

SLOPE

OPENING "A" MAX

USE FLASHING

(degrees)

(inches)

MODEL NO.

FLAT

0

15

V6F-8DM

0 - 6/12

26.6

16 - 1/8

V6F-8DM

6/12 - 12/12

45.0

20 - 3/8

V12F-8DM

Figure 15       FLASHING INSTALLATION 

Figure 16             STORM COLLAR 

 

Figure 17                   TERMINATION 

CAUTION

: Do not seal openings on the rooftop flashing.

Follow the installation instructions provided with the
termination being used.

Summary of Contents for C36EMW

Page 1: ...proved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see A...

Page 2: ...ION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE PG 4 5 9 FIRESTOP THIMBLE AND SPACERS PG 5 6 10 FLASHING AND TERMINATION PG 7 11 FINISHING YOUR FIREPLACE PG 8 12 MANTEL PG 8 13 GLASS DOORS PG 8 14 GAS...

Page 3: ...lace to the flue gas outlet of the termination is 11 5 feet for straight flue or a flue with one elbow set The maximum distance between elbows is 2 feet For systems with 2 elbow sets minimum height is...

Page 4: ...N A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace...

Page 5: ...gh the strain relief opening and electrical cover plate and make all the necessary connections iv Slide all wiring connections in the electrical housing as shown in figure 6b v Secure the electrical c...

Page 6: ...c space of a manufactured home To install the thimble assembly determine the distance between the ceiling joist and the roof framing Attach the adjustable thimble to the firestop spacer so that the as...

Page 7: ...n in figure 13 PENETRATING THE ROOF To maintain a 1 inch clearance to the pipe on a roof with a pitch a rectangular opening must be cut STEP 1 Determine the center point through which the pipe will pe...

Page 8: ...ly waterproof caulk around the perimeter of the collar to provide a proper seal Note Storm collar is required but can be installed after the home is sited TERMINATIONS SPARK ARRESTOR The fireplace sys...

Page 9: ...A mantel may be installed if desired see figure 20 Woodwork such as wood trims mantels or any other combustible material projecting from the front face must not be placed within 9 inches of the firep...

Page 10: ...r Use only a inch black iron pipe and appropriate fittings When installing a gas line a shut off valve designed for installation outside the appliance is recommended STEP 1 To install remove the knock...

Page 11: ...re 25 Pulling the handle out will free the outside air door to open Pushing the handle in will lock the door close FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER T...

Page 12: ...11 For more information visit www desatech com ILLUSTRATED PARTS...

Page 13: ...ONT 1 50 16502 BAG POLY 1 16 106683 01 LEG FIREBOX SUPPORT 2 51 16901 STRAPPING 7 16 10 5 17 56090 COLEMAN DECAL 1 52 20023 COLLAR STARTER 1 18 106687 01 COLLAR DAMPER CAN 1 53 20027 RETAINER REFRACTO...

Page 14: ...24 8DM 24 Double Wall Pipe 1 0 18 8DM 18 Double Wall Pipe 0 2 FST A Adjustable Firestop Thimble 1 1 V6F 8DM Roof Flashing 1 1 VSC1 8DM Storm Collar 1 1 RTL 8DM Round Cap Termination 1 1 VENT KITS USE...

Page 15: ...DM 36 8DM DOUBLE WALL PIPE 36 SECTION 9736A1236 36 8DM 48 8DM DOUBLE WALL PIPE 48 SECTION 9736A1248 48 8DM V6F 8DM ROOF FLASHING 0 6 12 PITCH 9736 5241 V6F 8DM V12F 8DM ROOF FLASHING 6 12 12 12 PITCH...

Reviews: