Summary of Contents for blt-in-36

Page 1: ...eplaces INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLATION AND OPERATING INSTRUCTIONS For Built in units Blt in 38 blt in 58 blt in 36 blt in 62 7 18 11 02 ...

Page 2: ......

Page 3: ...Specifications Page 6 BLT IN 62 Specifications Page 7 Installation Overview Page 8 Built In Installation Page 10 Wall Mount Installation Page 12 Fire Glass Media Installation Page 13 Installing the Front Page 14 Operating the Unit Page 15 Fireplace Maintenance Page 17 Warranty Page 18 Dealer Contact Information Back Page 1 ...

Page 4: ......

Page 5: ... fireplace and cord keep in a dry place free from excessive vibration and store so as to avoid damage This appliance is not intended for use by persons including children with reduced physi cal sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Never locat...

Page 6: ...C22 1 Canadian Elec trical Code in Canada or the ANSI NFPA 70 National Electrical Code in the United States Model Number BLT IN 38 Description Built In Appliance Voltage 12 Watts 10 5 Amps 2 Appliance Width Glass Stone 24 7 16 or 62 cm Appliance Height Glass Stone 19 1 8 or 48 5 cm Appliance Depth Glass Models 6 5 8 or 16 8 cm Appliance Depth Stone Models 7 5 16 or 18 5 cm Gross Weight Glass Model...

Page 7: ...76 or 193 cm 38 GLASS FRONT MODEL STONE FRONT MODELS 6 39 7 5 5 5 8 16 16 blt in 58 specifications This appliance has been tested in accor dance with the ETL Intertek Standards for fixed and location dedicated electric room appliances in the United States and Cana da If you need assistance during installa tion please contact your local dealer NOTE This appliance must be electrically wired and grou...

Page 8: ...In the absence of local codes us the current CSA C22 1 Canadian Elec trical Code in Canada or the ANSI NFPA 70 National Electrical Code in the United States Model Number BLT IN 36 Description Built In Appliance Voltage 12 Watts 10 5 Amps 2 Appliance Width 24 7 16 or 62 cm Appliance Height 19 1 8 or 48 5 cm Appliance Depth 7 5 16 or 18 5 cm Gross Weight 58 lbs or 26 5 kg Plug Location Right side Co...

Page 9: ... dance with the ETL Intertek Standards for fixed and location dedicated electric room appliances in the United States and Cana da If you need assistance during installa tion please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes us the current CSA C22 1 Canadian Elec trical Code in Canada or the ANSI...

Page 10: ... to persons A 15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases 1 Select a location that is not suscep tible to moisture dust and is away from high traffic locations and things that many catch fire or block openings such as drapes pillows furniture etc 2 If possible select a location near an existing electrical outlet for ease of electrical hook up...

Page 11: ...re 4 Figure 2 Figure 3 Locate fire glass media and set aside for later installation See Page 13 Remove sides of box Remove packaging surrounding the unit and front Discard packaging materials and store fireplace in a safe dry location 9 ...

Page 12: ...gure 5 Figure 5 Do not attempt to wire your own new outlets or circuits To reduce the risk of injury elec tric shock or fire use a licensed electrician Warning Warning Ensure that the Main ON OFF Switch is set to the OFF Position page 16 and that the circuit on which the fireplace is to be in stalled on has the power cut off at the service panel until instal lation is complete 10 ...

Page 13: ...n built in 1 Lift fireplace and insert into opening Ad just the unit to achieve the desired amount of depth Figure 6 2 Make sure that the power supply port is not behind the wall 3 Level the fireplace 4 Drive mounting screws into the mount ing brackets nailing flanges on the unit and the wall studs Figure 7 Figure 7 Figure 6 Power adaptor port Power adaptor port NOte Before you install Wall 11 ...

Page 14: ...acket to the wall Figure 8 Make sure it is level 2 Lift fireplace unit and insert the stakes for hanging into the keyholes on the back of the unit Figure 9 Figure 10 3 Check the appliance for stability ensur ing that the appliance will not pull free from the wall Figure 8 Figure 9 Figure 10 Wall NOte Before you install Stakes for hanging Stakes for hanging Mounting holes for wall bracket Height fr...

Page 15: ...ire Glass Media installation is the same for both Built in and Wall Mount installation methods It is not necessary to use all the media supplied NOte Before you install CLEANING THE MEDIA The media may contain a fine white dust that needs to be cleaned prior to installation Clean the media with soap drain rinse thoroughly and dry before placing into the tray Figure 12 Fire Glass Media Tray 13 ...

Page 16: ...ance wear safety glasses and gloves when handling glass 1 Lift fireplace front Figure 13 and line up the brackets with the four 4 shoulder screws on the side of the appliance body Figure 14 or Figure 15 2 Attach the front to the unit Built In Installation Wall Mount Installation Figure 13 Shoulder Screw Shoulder Screw Figure 14 Figure 15 14 ...

Page 17: ...uction 2 Attach the provided adaptor to the power port on the right hand side of the unit Figure 16 3 Plug unit into electrical outlet Wall Power adaptor port Do not attempt to wire your own new outlets or circuits To reduce the risk of injury electric shock or fire use a licensed electrician Warning Figure 16 15 ...

Page 18: ...sed to adjust the speed of the motor There are three indicators on the control panel is the power indicator it lights up when the fireplace is working and turns out when the fireplace is off indicates the status of the simulated flame It lights up when the flame simula tor component is working and will be flash ing when you adjust the flame indicates the speed of the motor It lights up when the fl...

Page 19: ...s to cool off before handling bulbs to avoid burns Warning led light bulb requirements Rating Voltage 12 Volts Rating Power 5 Watts BLT IN 38 3 Bulbs BLT IN 58 5 Bulbs BLT IN 36 3 Bulbs BLT IN 62 5 Bulbs caution Do not exceed 5 watts per bulb unit disposal Do not dispose with other household wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle...

Page 20: ...vice by contacting Amantii at 1 888 406 8764 or at 1503 7088 18th Avenue Burnaby British Columbia Canada V3N 0A2 Please have your proof of purchase catalogue model and serial num bers available when calling any and all service under the limited warranty requires a proof of purchase of the product Defects Should a product or part covered by this limited warranty be proven to be defective in materia...

Page 21: ...electric fireplaces www amantii com Date of Purchase Dealer Information ...