82
Transfer Direction
Control Commands
Scanner Host
Function
U1
U2
U3
Trigger switch control
U1:
Auto-off mode
U2:
Momentary switching mode
U3:
Alternate switching mode
PW
(Note 3)
Save
parameters
Parameters set by the control commands are saved to FLASH ROM.
VER
Request for software version
<Response from the scanner> Ver. n.nn
where n.nn is version number (Ex. Ver. 1.00)
VERF
Request for the parameter setting version
This command checks the version of the parameter settings made in
the scanner when the scanner is linked with the configuration
software (Scan Tune App).
<Response from the scanner> Ver.n.nn.mm where n.nn.mm is
version number (Ex. Ver.1.00.00)
and mm is parameter setting version.
ID
Request for scanner ID (serial number)
<Response from the scanner> ID.nnnnnn where nnnnnn is a serial
number (Ex. ID. 000001)
(Note 1) After receipt of one of the B1 to B3, LB, LG and LR commands, the scanner may need a maximum of 100 ms to
execute the command.
(Note 2) Beeping specified by control commands B1, BH1, BM1, and BL1 is dependent on the reading completion sound
and its length.
(Note 3) The PW can save settings into the FLASH ROM a maximum of 1,000,000 times due to the restrictions on the
EEPROM.