81
Appendix 2 Control Commands
Control commands refer to commands that are exchanged between the host computer and the scanner via the communications
line.
Control commands can be used only when a connection using SPP protocol is established.
Some of the control commands that the host computer issues are functionally equivalent to some parameters that can be set
with the QR-coded parameter menu (refer to Chapter 10). Control command settings have priority over settings made with the
QR-coded parameter menu.
Note that turning off the scanner will clear control command settings so that settings made with the QR-coded parameter
menu will take effect unless the PW command is sent to the scanner for saving control command settings into the FLASH
ROM.
If commands other than ones listed below are sent to the scanner, the scanner operation is not assured.
Transfer Direction
Control Commands
Scanner Host
Function
B1
B2
B3
(Note 1) (Note 2)
Sound
the
beeper
Within 100 ms from the receipt of any of the B1, B2 and B3
commands, the scanner beeps for the period specified below.
B1: Beeps for approx. 60, 80 or 120 ms once.
Or, beeps for approx. 70 ms twice.
B2: Beeps for approx. 120 ms
B3: Beeps for approx. 240 ms
Even if the beeping is prohibited or the scanner is on standby, the
beeper will be able to sound.
BH1, BM1, BL1
BH2, BM2, BL2
BH3, BM3, BL3
(Note 1) (Note 2)
Specifies the beeper tone.
Adding this command to the B1, B2 and B3 commands allows the
scanner to beep at the specified frequency.
H:
High (approx. 4.3 kHz)
M:
Medium (approx. 2.2 kHz)
L:
Low (approx. 1.5 kHz)
LB
(Note 1)
Light the blue indicator
LED.
Within 100 ms from the receipt of the LB command, the blue
indicator LED lights for approx. 500 ms.
LG
(Note 1)
Light the green indicator
LED.
Within 100 ms from the receipt of the LG command, the green
indicator LED lights for approx. 500 ms.
LR
(Note 1)
Light the red indicator
LED.
Within 100 ms from the receipt of the LR command, the red indicator
LED lights for approx. 500 ms.