15
7.1.1.3 Extracting AI (Application Identifier)-prefixed strings
If the scanner reads any of GS1-128, GS1 DataBar, and GS1Composite symbols (excluding linear components in a
UPC/EAN Composite symbol), it edits the data according to AIs and outputs it in the data transmission format
selected in the scanner (see Chapter 9, Section 9.3).
The "AI-prefixed string" extraction is available in two modes--AI split mode and AI parenthesizing mode. AIs to be
used for data editing are listed in (3) AI table later.
(1) AI split mode
In this mode, the scanner extracts strings prefixed with AIs specified (up to three types of AIs) and separates them
with the specified delimiters (selectable from headers/terminators, commas and tabs) instead of AIs to output them.
Extraction conditions
Extraction conditions
Choices
"Data transfer regardless of error result"
Permit/Prohibit
If the scanner fails to extract an AI-prefixed string when the "Data transfer regardless of error result" is permitted, it
outputs the data read as is without editing.
Delimiters
Header/terminator
Specifying a header/terminator as delimiters prefixes a header and suffixes a terminator to each element string
separated.
A scanner ID, code ID mark, the number of digits, prefix, and suffix can be also added to each element string if
their transmissions are enabled. The number of digits is the count of each element string edited.
Example Data read: (01)94901234567894(11)030808(13)030810
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Enable, Prefix/Suffix: None, BCC: Disable
AIs specified
Output data
01,11,13 [STX]94901234567894[ETX][STX]0006030808[ETX][STX]0006030810[ETX]
Comma
Specifying a comma as delimiters outputs comma-delimited data. No comma follows the tail of the data.
A header and terminator are added to the full string. None of a scanner ID, code ID mark, the number of digits,
prefix, and suffix is added even if their transmissions are enabled.
Example Data read: (01)94901234567894(11)030808(13)030810
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Disable, Prefix/Suffix: None, BCC: Disable
AIs specified
Output data
01,11,13 [STX]94901234567894,030808,030810[ETX]
Tab (ASCII 09H (HT))
Specifying a tab as delimiters outputs tab-delimited data. No tab follows the tail of the data.
A header and terminator are added to the full string. None of a scanner ID, code ID mark, the number of digits,
prefix, and suffix is added even if their transmissions are enabled.
Example Data read: (01)94901234567894(11)030808(13)030810
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Disable, Prefix/Suffix: None, BCC: Disable
AIs specified
Output data
01,11,13 [STX]94901234567894[TAB]030808[TAB]030810[ETX]
Summary of Contents for QK30-U
Page 1: ...2D Code Scanner Fixed type QK30 U User s Manual...
Page 22: ...11...
Page 86: ...75 USB interface to the host USB COM interface USB keyboard default interface...
Page 89: ...78 Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...
Page 90: ...79 Header USB keyboard interface...
Page 91: ...80 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...
Page 99: ...88 Speaker control Other settings Disable Enable default Indicator LEDs Disable Enable default...
Page 113: ...2D Code Scanner Fixed type QK30 U User s Manual First Edition May 2014 DENSO WAVE INCORPORATED...