143
Barcode Handy Terminal
“2: SET PING” (PING Options Setting Screen)
1.
Select “2: SET PING” at the TEST PING menu and then press the
ENT
key.
The current settings are displayed.
[1: DESTINATION IP]:
Specifies the IP address of the host computer to be pinged.
[2:DATA SIZE]:
Specifies the data size of the echo request.
[3:INTERVAL]:
Specifies the echo request interval (in units of 100 ms).
[4:TIMEOUT]:
Specifies the timeout period (in units of 100 ms) for the echo request.
[5:COUNT]:
Specifies the number of echo requests to be sent.
[6:SEND TYPE]:
Selects the echo request send timing (TYPE 1 or TYPE 2).
(Refer to “PING Echo Request Transmission Timing (SEND TYPE)” on the following page for details.)
2.
Use the cursor keys ([
▲
] [
▼
]) or numerical keys ([1] [2] [3] [4] [5] [6]) to highlight the item to be
set, and then press the
ENT
key.
The mode changes to entry mode and the cursor is displayed.
Use the cursor keys ([
◄
] [
►
]) to highlight the “6: SEND TYPE” setting.
3.
Enter the setting values with the numerical keys and dot key.
To delete a single character, press the
BS/C
key. To delete the entire entry,
press and hold the
BS/C
key, or press the
SF
key and
BS/C
key simultaneously.
4.
Enter the setting values and then press the
ENT
key.
Press and hold the
BS/C
key to return to the TEST PING menu.
Entry Range for DATA SIZE, INTERVAL, TIMEOUT, and COUNT
Item Allowable
Entry
range
Default
DATA SIZE
4 to 1472
56
INTERVAL
0 to 65535
10
TIMEOUT
0 to 65535
10
COUNT 0
*
to 65535
4
* Specifying zero (0) will set the number of echo requests to “infinite,” meaning that echo requests will be
sent continuously until the PING test is aborted.
If a value outside the allowable entry range listed above is specified, the nearest value within the range
will automatically be applied.