smartDEN Opener
User Manual
24 Apr 2018
- 87 -
Date
- sets the date of the onboard RTC module. Format is (dd/mm/yyyy). Date can be
selected when clicked on the text field when
Auto Synchronization
option is not checked.
Calendar will pop-up and date selection can be made (
Figure 10.37
).
Day
of
Week
- shows current day of week stored in
smartDEN Opener's
onboard RTC
module. This parameter is read only;
Time
- sets the time of the onboard RTC module. Format is (hh/mm). Time can be set when
Auto
Synchronization
option is not checked;
Time
Zone
- time zone selection drop-down list.
Auto
Synchronization
- enables
Date
and
Time
auto synchronization from ntp server.
When checked
Time
Server
and
Synchronization
Period
fields are shown. Time got from
NTP server will be Greenwich Mean Time (GMT).
This parameter will work only in STA network mode.
Time
Server
- this could be any public or private NTP server. On the right is located port
number. There are 30 allowed symbols reserved for this parameter (see
Appendix 3
);
Synchronization
Period
- this is the time in which
Date
/
Time
will be updated from NTP
server. Its
could be in range 10 ÷ 1440 minutes;
Daylight
Savings
- daylight savings time can be defined from this option. In the period
defined one hour will be added to current time;
Start
Period
- this is the start period of
Daylight Savings Time
. On this day at 03:00 am,
time shifts forward to 04:00 am;
End
Period
- this is the end period of
Daylight Savings Time
. On this day at 04:00 am,
time returns back to 03:00 am;
Log
Date
and
Time
Events
- used to write messages to system log file about NTP server
successful / unsuccessful synchronization events;