smartDEN Opener
User Manual
24 Apr 2018
- 60 -
Send notification On
- this parameter allows sending MQTT notifications on specified
alarm:
o
Never
-
smartDEN Opener
will not send any notifications about selected digital input;
o
Low Alarm
- controller will send notifications only on high to low transition of the digital
input (falling edge);
o
High Alarm
- controller will send notifications only on low to high transition of the digital
input (rising edge);
o
Any Alarm
- will send notifications on both LOW ALARM event and HIGH ALARM event;
In order to use this parameter MQTT settings should be set properly and
Admin/Guest
User
accounts should be enabled in the way desired. Note that notifications are
available in
DAE-aModules
App with MQTT enabled.
Send Email On
- this parameter allows sending emails on specified alarm:
o
Never
-
smartDEN Opener
will not send any emails about selected digital input;
o
Low Alarm
- controller will send emails only on high to low transition of the digital input
(falling edge);
o
High Alarm
- controller will send emails only on low to high transition of the digital input
(rising edge);
o
Any Alarm
- will send emails on both LOW ALARM event and HIGH ALARM event;
Log On
- this parameter allows writing to Events Log only on specified alarm:
o
Never
-
smartDEN Opener
will not write log messages about selected digital input;
o
Low Alarm
- controller will write logs only on high to low transition of the digital input
(falling edge);
o
High Alarm
- controller will write logs only on low to high transition of the digital input
(rising edge);
o
Any Alarm
- will write logs on both LOW ALARM event and HIGH ALARM event;
Controls
- this parameters specifies which output is controlled by this digital input:
o
Nothing
- this digital input will not control any output. If some of the previous settings are
set it will be used for monitoring some process (for example if used barrier sensor it may
send notification when it is crossed through);
o
Relay 1
- this digital input will control Relay 1;
o
Relay 2
- this digital input will control Relay 2;
o
Main
- this digital input will control Main Controlled Device;
Control On
- specifies on which alarm the digital input will control the selected output:
o
Low Alarm
- the digital input will control selected output only on high to low transition
(falling edge);
o
High Alarm
- the digital input will control selected output only on low to high transition
(rising edge);
o
Any Alarm
- the digital input will control selected output on both LOW and HIGH ALARM
events;
Control Mode
(
Controls
is selected to be "Relay1" or "Relay2"):
o
Normal
- in this mode the selected relay will turn on when digital input generates HIGH
ALARM and will turn off when LOW ALARM event is generated;
o
Inversed
- in this mode the selected relay will turn on when digital input generates LOW
ALARM event and will turn off when HIGH ALARM event is generated;
o
Toggle
- in this mode, depending on the selected
Control On
value, the state of the
relay will be inversed (toggled).
Control Mode
(
Controls
is selected to be "Main"):