smartDEN Opener
User Manual
24 Apr 2018
- 59 -
10.6. I/O Setup
10.6.1.
Digital Inputs
Figure 10.15.
Digital Inputs page
smartDEN Opener
has three digital inputs, which can control different or same peripheral
(Main Controlled Device or some relay). Every digital input has these parameter:
Select Digital Input
- dropdown menu to select one of the digital inputs;
Description
- specifies the name of the digital input (for example "Button"). There are up 10
allowed symbols for description (see
Appendix 3
);
Enable Alarm
- this will allow the digital input to control its peripheral (if desired) or just
write to log, send notifications or emails (if enabled). For example on below alarm is
enabled but
Controls
,
Send notification On
,
Log On
and
Send Email On
are not desired,
so nothing will happen on "Any Alarm". LOW ALARM EVENT is generated on HIGH (ON) to
LOW (OFF) transition of the digital input. HIGH ALARM event is generated on LOW (OFF)
to HIGH (ON) transition.
Figure 10.16.
Digital Inputs alarms