smartDEN Opener
User Manual
24 Apr 2018
- 53 -
o
Auto Close
- this parameter closes the Main Controlled Device after the time in seconds,
specified by the
Auto Close time
parameter. This time can be from 1 to 65535
seconds;
Send notification On
-
this parameter allows sending notification on specified state of the
Main Controlled Device. There are several available options:
o
Never
- this option will not send notifications about Main Controlled Device;
o
State Change
- this will send notifications on
OPENED
and
CLOSED
states;
o
Open
- this option will send you notifications on
OPENED
state;
o
Close
- this option will send you notifications on
CLOSED
state;
Note:
Admin User
must be enabled and proper MQTT settings applied.
Send Email On
-
This parameter allows sending emails on specified state of the Main
Controlled Device. There are several available options:
o
Never
- this option will not send emails about Main Controlled Device;
o
State Change
- this will send email on
OPENED
and
CLOSED
states;
o
Open
- this option will send you email on
OPENED
state;
o
Close
- this option will send you email on
CLOSED
state;
Note:
Emails must be enabled with proper settings applied.
Log On
-
This parameter allows logging Main Controlled Device's states. There are several
available options:
o
Never
- this option will not log Main Controlled Device's state changes;
o
State Change
- this will log OPENED, CLOSED and STOPPED states;
o
Open
- this option will log OPENED state;
o
Close
- this option will log CLOSED state;
Note:
Enable Writing to Logs
options must be enabled.
Attach Relay
- allows you to control one of the onboard relays depend on the state of the
Main Controlled Device. There are three available options:
o
Nothing
- no relay is attached;
o
Relay 1
- if you select this option Relay 1 will be controlled by the Main Controlled
Device. Relay action will be determined from
Relay Action
option;
o
Relay 2
- this option will attach Relay 2 to Main Controlled Device. Relay action will be
determined from
Relay Action
option;
Relay Action
-
if you attach relay to Main Controlled Device, you can choose its action from
these several options:
o
Turn On While Opening and Closing
- this option will turn on the relay during the time
the Main Controlled Device opens and closes. This option is suitable for Warning
Lamps;
o
Turn Off While Opening and Closing
- this option will turn off the relay during the time
the Main Controlled Device opens and closes;
o
Turn On When Opened
- this option will turn on the relay when the Main Controlled
Device is
OPENED
. Suitable for lamps;
o
Turn Off When Opened
- this option will turn off the relay when the Main Controlled
Device is
OPENED
. Suitable for heaters in the winter;