5

 

6.

 

Use the APP for Wi

-

Fi configuration. The APP will provide instructions on operating procedures. Please 

verify that the controller you purchased is the Wi

-

Fi version. The Wi

-

Fi connection indicator will turn on 

after connecting to Wi

-

Fi. (only on the UNO

-

C07X011 model)

 

7.

 

The controller was calibrated before leaving the factory, and no additional calibration is required. If the 
controller is affected by the environment at your site, please contact the distributor for manual 
calibration.

 

8.

 

This controller has built-in multiple sets of precision sensors. Collision and vibration during transportation 
may affect its readings. It is recommended to turn it on and install it, and then wait for about one hour 
until the chamber reaches balance.

 

9.

 

After the device is turned on, the sensor needs to warm

-

up for 10 seconds or less for PM2.5, PM10, and 

carbon dioxide, and 5 minutes for formaldehyde, carbon monoxide, ozone, and TVOC.

 

10.

 

Sensor data is updated every 3 to 6 seconds (depending on the type of sensor)

 

11.

 

When UNOnext is connected to the central control unit, and the central control unit is in control, and 
UNOnext will indicate that it is currently in remote control mode.

 

12.

 

Regardless of whether the central control unit sends a control command, the user presses a physical key, 
or uses the APP for control, UNOnext will perform the last command that was sent

 

13.

 

If it is used in a place of business and the owner does not want to let users on site turn it on and off or use 
the APP to control the device, the owner can use a Modbus command to engage the control lock. When 
the control lock is engaged, local users cannot perform any operations. If the user manually presses the 
switch, the image below appears, which means that it cannot be operated by local users.

 

 
 
 
 
 
 
 
 

 

14.

  Pressing the button in "air quality sensing" mode will turn the air quality indicator on/off. When the 

power is turned off, the device will remember its last state.

 

15.

 

CO2 component automatic calibration 

 

The CO2 component is a precision instrument. This product was calibrated at the factory before shipping. 
After a week of continuous operation, it will be automatically calibrated every week. If the component 
encounters vibration when it is reinstalled in a different place, the data values may drift.

 

 

 

Diagram

 

Pressing Mode

 

Description

 

 

Remote control

 

Connect to the central control unit, which will send control commands.

 

[Note] Follow the instructions below to facilitate the automatic calibration of CO2 components.

 

 

The product needs continuous power supply, so install it in a fixed position 

 

 

The indoor environment reaches the level of the outdoor environment for four consecutive hours 
each week

 

Summary of Contents for UNO-C07X011

Page 1: ...1 UNOnext Indoor Air Quality Monitor UNOC07X011 Packaged user manual ver 1 0 9 2020 9 17...

Page 2: ...r information replaced icons 1 2 1 Added a description of the NCC s radio wave regulations 1 2 2 Organized the layout added notices on CO2 automatic calibration 1 2 3 Added a description 4 5 Start Con...

Page 3: ...ions and sensitive places such as nursing homes and day care centers and detects various types of air pollution that may have an adverse effect on the human body UNOnext provides NFC tags which can be...

Page 4: ...will be used as the switch of the air quality indicator DIP switch No 8 must also be pushed up 5 AutoMode will turn ventilation equipment on and off depending whether the air quality exceeds the thres...

Page 5: ...a control command the user presses a physical key or uses the APP for control UNOnext will perform the last command that was sent 13 If it is used in a place of business and the owner does not want to...

Page 6: ...ply Power consumption 5W Operating temperature 0 C 50 C Operating humidity 0 RH 95 RH Non condensing Storage 20 C 70 C Protection level IP20 Certification NCC FCC IC CE JRF Accessories Wall mount x 1...

Page 7: ...9 24V DC output Switch Number Switch Definition ON OFF 1 Modbus terminal resistor 2 Modbus slave position 3 3 Modbus slave position 2 4 Modbus slave position 1 5 Modbus slave position 0 6 Maximum wind...

Page 8: ...sition of each device is 0xD0 and the slave position of each device must not be repeated In order for the central control unit to receive the correct data the second to fourth pins of the DIP switch m...

Page 9: ...tches 8 On Off Mode 3 Control single speed ventilation equipment through relay This controller supports relay output The controller can control a 12V or 24V DC relay through the relay which can be tri...

Page 10: ...for power boxes in multiple countries but the power box must be installed horizontally as shown in Figure 1 2 This controller uses a 9 24V DC power supply AC power must be converted to the required p...

Page 11: ...s product is made in Taiwan The place of origin is No 256 Yangguang St Neihu Dist Taipei City Taiwan R O C iOS APP Android APP UNOweb XI APP and website links UNOnext is equipped with wireless technol...

Page 12: ...e equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This...

Page 13: ...13 XIV Product dimensions I Device dimensions...

Page 14: ...14 II Wall mount dimensions...

Reviews: