background image

10

 

X. Wiring diagram 

 

Installing the external temperature sensor cable (optional)

 

The product

s built

-

in temperature sensor module has an accuracy of +/

-

 1°C. If you need more precise temperature 

sensing, the product can be equipped with temperature sensor cable accessories, allowing for accuracy of about +/

-

 0.3°C, 

which can meet more precise environment temperature control requirements. After installation, the default temperature 
display on the screen will be replaced with the temperature detected by the external temperature sensor cable

 

XI. Installation instructions

 

I. Notice

 

1.

 

The air quality sensor is recommended to be installed at a height of 80

-

150 cm.

 

2.

 

The sensor must be installed in a location with air circulation.

 

3.

 

In order to ensure the sensor's accuracy, avoid installing the sensor near sunlight and heat sources.

 

4.

 

UNOnext has a variety of precision sensors inside. Please do not violently strike or cause it to vibrate during 
installation, as that may cause the sensor readings to drift, and will it take longer to enter a stable and balanced 
state.

 

II. Installation method

 

1.

 

Install the wall mount accessory for UNOnext. Use the wall plugs included in the box to install it on the wall, or 
install in a power box. The wall mount has screw hole spacing (60mm and 84mm) suitable for power boxes in 
multiple countries, but the power box must be installed horizontally as shown in Figure 1.

 

2.

 

This controller uses a 9

-

24V DC power supply. AC power must be converted to the required power source before 

installation, or use the power supply provided along with this controller. Verify electrical characteristics in 

IV. 

Technical parameters

” 

for details

 

3.

 

Verify that the power supply and data lines are laid out according to specifications before installation

 

4.

 

As shown in Figure 2, install UNOnext on the wall mount and verify that all four buckles are installed and fixed.

 

5.

 

As shown in Figure 3, use a hexagonal screwdriver to fasten the M4 hex socket screws to complete the installation

 

III. Power-on verification

 

1.

 

If the device has been installed, the power indicator will light up after the power is connected, and the air quality 
indicator will turn blue, which means the device is being turned on at this time. If green or yellow appear, it 
means that the device has completed booting and the current air quality status has been displayed. If the power 
indicator does not light up, please verify that the power cord is properly connected and there is power supply. 

 

2.

 

UNO

-

C07X011 has Bluetooth and Wi

-

Fi functionality. Users can go to the iPhone app store or Android play store 

to download the UNOnext APP. After opening the APP, the serial number of the device and sensor values will be 
displayed. You can refresh to see if the device is already online.

 

Controller

 

 

Summary of Contents for UNO-C07X011

Page 1: ...1 UNOnext Indoor Air Quality Monitor UNOC07X011 Packaged user manual ver 1 0 9 2020 9 17...

Page 2: ...r information replaced icons 1 2 1 Added a description of the NCC s radio wave regulations 1 2 2 Organized the layout added notices on CO2 automatic calibration 1 2 3 Added a description 4 5 Start Con...

Page 3: ...ions and sensitive places such as nursing homes and day care centers and detects various types of air pollution that may have an adverse effect on the human body UNOnext provides NFC tags which can be...

Page 4: ...will be used as the switch of the air quality indicator DIP switch No 8 must also be pushed up 5 AutoMode will turn ventilation equipment on and off depending whether the air quality exceeds the thres...

Page 5: ...a control command the user presses a physical key or uses the APP for control UNOnext will perform the last command that was sent 13 If it is used in a place of business and the owner does not want to...

Page 6: ...ply Power consumption 5W Operating temperature 0 C 50 C Operating humidity 0 RH 95 RH Non condensing Storage 20 C 70 C Protection level IP20 Certification NCC FCC IC CE JRF Accessories Wall mount x 1...

Page 7: ...9 24V DC output Switch Number Switch Definition ON OFF 1 Modbus terminal resistor 2 Modbus slave position 3 3 Modbus slave position 2 4 Modbus slave position 1 5 Modbus slave position 0 6 Maximum wind...

Page 8: ...sition of each device is 0xD0 and the slave position of each device must not be repeated In order for the central control unit to receive the correct data the second to fourth pins of the DIP switch m...

Page 9: ...tches 8 On Off Mode 3 Control single speed ventilation equipment through relay This controller supports relay output The controller can control a 12V or 24V DC relay through the relay which can be tri...

Page 10: ...for power boxes in multiple countries but the power box must be installed horizontally as shown in Figure 1 2 This controller uses a 9 24V DC power supply AC power must be converted to the required p...

Page 11: ...s product is made in Taiwan The place of origin is No 256 Yangguang St Neihu Dist Taipei City Taiwan R O C iOS APP Android APP UNOweb XI APP and website links UNOnext is equipped with wireless technol...

Page 12: ...e equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This...

Page 13: ...13 XIV Product dimensions I Device dimensions...

Page 14: ...14 II Wall mount dimensions...

Reviews: