IV. Detailed Description

 

1.

 

The power indicator will light up after power is connected. If the power indicator does not light up, please make sure 
that the power cord is firmly installed.

 

2.

 

The air quality indicator will turn blue after the device is turned on, which means that it is booting up. After booting is 
complete, it will change color according to the air quality status, in which green is good, yellow is normal, red is poor, 
and purple is polluted.

 

3.

 

UNOnext has built

-

in multiple sets of sensors, and the values will be displayed in a rotation. If an item exceeds the 

threshold, it will be displayed on the screen.

 

4.

 

Keypad functions will change based on software settings; the default is 

smart sensor control

” 

 

If it is set to 

smart sensor control", double

-

press the button (within 5 seconds) to switch the wind speed and work 

mode. The default is AutoMode and may be switched into the following modes. If the interval between key presses is 
more than five seconds, ventilation equipment will be turned on and off. It will enter AutoMode when it is turned on 
again. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

If it is set to "air quality sensing" mode, the keys will be used as the switch of the air quality indicator (DIP switch No. 8 
must also be pushed up)

 

5.

 

AutoMode will turn ventilation equipment on and off depending whether the air quality exceeds the threshold or not. 
There are two control modes: Turbo and UNOECO. Users can set a threshold on the APP to determine activation 
conditions (only on the UNO

-

C07X011 model)

 

3. Indoor air quality indicator description

 

Diagram

 

AutoMode menu

 

Description

 

 

Turbo

 

If it exceeds the threshold, ventilation equipment will operate at full speed and exchange air 
until the air quality improves

 

 

UNOECO

 

Depending on air quality, the ventilation equipment will automatically switch between differ-
ent wind speeds to achieve the three major indicators –

 

silent, power saving, and health 

 

The default equipment activation standard for CO2 is 1,000 ppm, PM2.5 is 28 ug/m

3

, PM10 is 

60ug/m

3

, which can be adjusted in the APP, but the color of the indicator light is based on the 

default range

 

Indoor air quality 

indicator

 

Color of indicator 
(status)

 

PM2.5 

 

(ug/m

3

)

 

PM10 

 

(ug/m

3

)

 

CO2 

 

(ppm)

 

0

-

80

 

Green (Good)

 

0

-

28

 

0

-

60

 

400

-

800

 

81

-

100

 

Yellow (Regular)

 

29

-

35

 

61

-

75

 

801

-

1000

 

101

-

400

 

Red (Poor)

 

36

-

140

 

76

-

300

 

1001

-

4000

 

401

 

Purple (Polluted)

 

>141

 

>301

 

>4001

 

Turn off 

ventilation 

equipment

 

AutoMode

 

Manual 

control low 

speed

 

Manual 

control 

medium 

speed

 

Manual 

control high 

speed

 

Summary of Contents for UNO-C07X011

Page 1: ...1 UNOnext Indoor Air Quality Monitor UNOC07X011 Packaged user manual ver 1 0 9 2020 9 17...

Page 2: ...r information replaced icons 1 2 1 Added a description of the NCC s radio wave regulations 1 2 2 Organized the layout added notices on CO2 automatic calibration 1 2 3 Added a description 4 5 Start Con...

Page 3: ...ions and sensitive places such as nursing homes and day care centers and detects various types of air pollution that may have an adverse effect on the human body UNOnext provides NFC tags which can be...

Page 4: ...will be used as the switch of the air quality indicator DIP switch No 8 must also be pushed up 5 AutoMode will turn ventilation equipment on and off depending whether the air quality exceeds the thres...

Page 5: ...a control command the user presses a physical key or uses the APP for control UNOnext will perform the last command that was sent 13 If it is used in a place of business and the owner does not want to...

Page 6: ...ply Power consumption 5W Operating temperature 0 C 50 C Operating humidity 0 RH 95 RH Non condensing Storage 20 C 70 C Protection level IP20 Certification NCC FCC IC CE JRF Accessories Wall mount x 1...

Page 7: ...9 24V DC output Switch Number Switch Definition ON OFF 1 Modbus terminal resistor 2 Modbus slave position 3 3 Modbus slave position 2 4 Modbus slave position 1 5 Modbus slave position 0 6 Maximum wind...

Page 8: ...sition of each device is 0xD0 and the slave position of each device must not be repeated In order for the central control unit to receive the correct data the second to fourth pins of the DIP switch m...

Page 9: ...tches 8 On Off Mode 3 Control single speed ventilation equipment through relay This controller supports relay output The controller can control a 12V or 24V DC relay through the relay which can be tri...

Page 10: ...for power boxes in multiple countries but the power box must be installed horizontally as shown in Figure 1 2 This controller uses a 9 24V DC power supply AC power must be converted to the required p...

Page 11: ...s product is made in Taiwan The place of origin is No 256 Yangguang St Neihu Dist Taipei City Taiwan R O C iOS APP Android APP UNOweb XI APP and website links UNOnext is equipped with wireless technol...

Page 12: ...e equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This...

Page 13: ...13 XIV Product dimensions I Device dimensions...

Page 14: ...14 II Wall mount dimensions...

Reviews: