background image

7

 

DIP Switches

 

Terminal block

 

VII. Product interface definition

 

Pin

 

Pin name

 

Definition

 

1

 

GND

 

Grounding

 

2

 

AI

1

 

Analog input 1 –

 

 

External temperature sensor

 

3

 

AI2

 

Analog input 2

 

4

 

NO4

 

Relay normal open 

-

 HF

 

5

 

NO3

 

Relay normal open 

-

 MF

 

6

 

NO2

 

Relay normal open 

-

 LF

 

7

 

NO1

 

 Relay normal open–

 

ON/OFF

 

8

 

B2

 

Modbus slave B

 

9

 

A2

 

Modbus slave A

 

10

 

B1

 

Modbus host B

 

11

 

A1

 

Modbus host A

 

12

 

GND

 

Grounding

 

13

 

Vin

 

9

-

24V DC input

 

14

 

Vout

 

9

-

24V DC output

 

Switch 

 

Number

 

Switch Definition

 

ON

 

OFF

 

1

 

Modbus terminal resistor

 

 

 

2

 

Modbus slave position [3]

 

 

 

3

 

Modbus slave position [2]

 

 

 

4

 

Modbus slave position [1]

 

 

 

5

 

Modbus slave position [0]

 

 

 

6

 

Maximum wind speed [1]

 

 

 

7

 

Maximum wind speed [0]

 

 

 

8

 

Control mode selection

 

 

 

The above are the default states of DIP switches

 

Table 1. Terminal block pin function definition

 

Table 2. DIP switch function definition

 

VIII. Wiring diagram 

 

Connecting to the central control unit

 

The central control unit can read the sensor data of UNOnext and the status of the ventilation equipment via the RS485 

physical line and the Modbus RTU protocol

 

Summary of Contents for UNO-C07X011

Page 1: ...1 UNOnext Indoor Air Quality Monitor UNOC07X011 Packaged user manual ver 1 0 9 2020 9 17...

Page 2: ...r information replaced icons 1 2 1 Added a description of the NCC s radio wave regulations 1 2 2 Organized the layout added notices on CO2 automatic calibration 1 2 3 Added a description 4 5 Start Con...

Page 3: ...ions and sensitive places such as nursing homes and day care centers and detects various types of air pollution that may have an adverse effect on the human body UNOnext provides NFC tags which can be...

Page 4: ...will be used as the switch of the air quality indicator DIP switch No 8 must also be pushed up 5 AutoMode will turn ventilation equipment on and off depending whether the air quality exceeds the thres...

Page 5: ...a control command the user presses a physical key or uses the APP for control UNOnext will perform the last command that was sent 13 If it is used in a place of business and the owner does not want to...

Page 6: ...ply Power consumption 5W Operating temperature 0 C 50 C Operating humidity 0 RH 95 RH Non condensing Storage 20 C 70 C Protection level IP20 Certification NCC FCC IC CE JRF Accessories Wall mount x 1...

Page 7: ...9 24V DC output Switch Number Switch Definition ON OFF 1 Modbus terminal resistor 2 Modbus slave position 3 3 Modbus slave position 2 4 Modbus slave position 1 5 Modbus slave position 0 6 Maximum wind...

Page 8: ...sition of each device is 0xD0 and the slave position of each device must not be repeated In order for the central control unit to receive the correct data the second to fourth pins of the DIP switch m...

Page 9: ...tches 8 On Off Mode 3 Control single speed ventilation equipment through relay This controller supports relay output The controller can control a 12V or 24V DC relay through the relay which can be tri...

Page 10: ...for power boxes in multiple countries but the power box must be installed horizontally as shown in Figure 1 2 This controller uses a 9 24V DC power supply AC power must be converted to the required p...

Page 11: ...s product is made in Taiwan The place of origin is No 256 Yangguang St Neihu Dist Taipei City Taiwan R O C iOS APP Android APP UNOweb XI APP and website links UNOnext is equipped with wireless technol...

Page 12: ...e equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This...

Page 13: ...13 XIV Product dimensions I Device dimensions...

Page 14: ...14 II Wall mount dimensions...

Reviews: