15
Installation and Operating Manual for RPI M15A M20A Solar Inverter V1.0 2016-03-18
4 Product overview
4.4.2 Grounding connection
Fig. 4.3:
Position of the grounding connection on the inverter
The inverter housing can be grounded by means of the ground-
ing connection.
M4 screw, spring washer, flat washer and serrated washer are
fitted to the inverter.
4.4.3 AC terminal (AC OUTPUT)
Fig. 4.4:
Position of the AC terminal on the inverter
The inverter is connected to the public grid by means of the AC
terminal.
Purpose:
● To supply alternating current to the public grid.
● To supply power to the display when no supply voltage is
available from the solar modules.
Usable grid types
● Grids with 3 phases and a neutral conductor: 3P4W
(L1, L2, L3, N, PE)
● Grids with 3 phases, no neutral conductor: 3P3W
(L1, L2, L3, PE).
Required plug type:
Amphenol C16-3 (C016 20E004 800 2)
The AC plug is included in the delivery.