9 Settings
Installation and Operating Manual for RPI M15A M20A Solar Inverter V1.0 2016-03-18
132
4.
Enter the password that you received from Delta customer
service.
Use the
and
buttons to set the individual digits.
Press the
ENT
button to confirm a digit.
3
3
3
3
ENT
21. Jun 2013 09:30
Password
5.
Using the
and
buttons, select the
Reactive Power
Control
entry and press the
ENT
button.
Active Power Control
Reactive Power Control
21. Jun 2013 09:30
Active / Reactive Power
6.
Using the
and
buttons, select the
Constant Reac-
tive Power
entry and press the
ENT
button.
Q (U)
Constant cos φ
Constant Reactive Power
cos φ (P)
21. Jun 2013 09:30
Reactive Power Control
Switching the function on/off
1.
Using the
and
buttons, select the
Mode
entry and
press the
ENT
button.
0
[
]
[
]%
Reactive Power (Q/Sn)
Mode
OFF
[
]
21. Jun 2013 09:30
Reactive Power Control
→ The currently set mode is highlighted and can be
changed.
0
[
]
[
]%
Reactive Power (Q/Sn)
Mode
OFF
[
]
21. Jun 2013 09:30
Reactive Power Control
2.
Using the
and
buttons, select a mode and press
the
ENT
button.
0
[
]
[
]%
Reactive Power (Q/Sn)
Mode
ON
[
]
21. Jun 2013 09:30
Reactive Power Control