163
Installation and Operating Manual for RPI M15A M20A Solar Inverter V1.0 2016-03-18
14 Technical data
Mechanical design
RPI M15A
RPI M20A
Dimensions (W x H x D)
612 x 625 x 278 mm
Weight
43 kg
Cooling
Fan
AC connection type
AC plug Amphenol C16-3 (C016 20E004 800 2)
DC terminal type
Multi-Contact MC4
Communications interfaces
2 x RS485, 1 x dry contact, 1 x external power off (EPO)
General specifications
RPI M15A
RPI M20A
Delta model name
RPI-M15A
RPI-M20A
Delta part number
RPI153FA0E0000
RPI203FA0E0000
Maximum efficiency
98.3%
98.4%
EU efficiency
97.9%
98.1%
Operating temperature range
-25 ... +60 °C
Operating temperature range without limiting
-25 ... +40 °C
-25 ... +47 °C
5)
Storage temperature range
-25 ... +60 °C
Relative humidity
0 ... 100 %, non-condensing
Maximum operating altitude
2000 m above sea level
Standards and Directives
RPI M15A
RPI M20A
Protection class
IP65
Safety class
I
Contamination level
II
Overload behaviour
Current limiting, power limiting
Safety
IEC 62109-1 / -2, CE conformity
EMC
EN 61000-6-2, EN 61000-6-3
Noise immunity
IEC 61000-4-2 / -3 / -4 / -5 / -6 / -8
Harmonic distortion
EN 61000-3-2
Fluctuations and flicker
EN 61000-3-3
Grid connection guidelines
See www.solar-inverter.com
5)
The full power is available up to 47 °C if the nominal voltages are present on the AC and DC sides.