Description
Factory default
Trap Inform Timeout (seconds)
Entering the Trap Inform Timeout. The range is 0 to 2147.
Note:
It’s only be activated the configuration when you select the Trap
version to SNMPv2c.
3
Trap Inform Retry Times
Entering the Trap Inform Retry Times. The range is 0 to 255.
Note:
It’s only be activated the configuration when you select the Trap
version to SNMPv2c.
5
Trap Probe Security Engine ID
Indicates the SNMP trap probe security engine ID mode of operation.
Possible values are:
Enabled: Enable SNMP trap probe security engine ID mode of operation.
Disabled: Disable SNMP trap probe security engine ID mode of operation.
When is enabled, the ID will be probed automatically. Otherwise, the ID specified in
this field is used.
Note:
It’s only be activated the configuration when you select the Trap
version to SNMPv3.
Enabled
Trap Security Engine ID
Indicates the SNMP trap security engine ID. SNMPv3 sends traps and informs use
USM for authentication and privacy. A unique engine ID for these traps and informs
is needed. When "Trap Probe Security
Engine ID" is enabled, the ID will be probed automatically. Otherwise, the ID
specified in this field is used. The string must contain an even number (in
hexadecimal format) with number of digits between 10 and 64, but all-zeros and
all-'F's are not allowed.
Note:
It’s only be activated the configuration when you select the Trap
version to SNMPv3.
None
Trap Security Name
Indicates the SNMP trap security name. SNMPv3 traps and informs using USM for
authentication and privacy. A unique security name is needed when traps and
informs are enabled.
Note:
It’s only be activated the configuration when you select the Trap
version to SNMPv3.
None
3.6.3
Communities
Configure SNMPv3 communities table on this page. The entry index key is Community.
Click “ Add New Entry” to add a new communities.
Summary of Contents for DVS-G928 series
Page 1: ......
Page 12: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual 1 6 _1 MEMO...
Page 15: ...Chapter 2 User Interface Introduction 2 3 2_ You can use to list the commands...
Page 18: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual 2 6 _2 MEMO...
Page 130: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual 3 112 _3 MEMO...
Page 141: ...Chapter 4 IEXplorer Utility Introduction 4 11 4_ MEMO...
Page 142: ...A 1 A Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2...
Page 144: ...Appendix A Private MIB Group A 3 A_ MEMO...
Page 145: ...B 1 B Appendix B MODBUS TCP Map Table of Contents B 1 MODBUS TCP Map B 2...
Page 148: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual B 4 _B MEMO...
Page 206: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual C 58 _C MEMO...