A p p e n d i x B M O D B U S T C P M a p
C - 4 7
C_
Deferred
Transmissions
UDINT
Frames for which first transmission
attempt is delayed because the
medium is busy
Late Collisions
UDINT
Number of times a collision is
detected later than 512 bit-times
into the transmission of a packet
Excessive
Collisions
UDINT
Frames for which transmission fails
due to excessive collisions
MAC Transmit
Errors
UDINT
Frames for which transmission fails
due to an internal MAC sublayer
transmit error
Carrier Sense
Errors
UDINT
Times that the carrier sense
condition was lost or never
asserted when attempting to
transmit a frame
Frame Too Long
UDINT
Frames received that exceed the
maximum permitted frame size
MAC Receive
Errors
UDINT
Frames for which reception on an
interface fails due to an internal
MAC sublayer receive error
10
Get
Interface Label
SHORT_STRING
Human readable identification
Common Services
Service
Code
Need in Implementation
Service name
Description of Service
Class
Instance
0x0E
V
V
Get_Attribute_Single
Returns the contents of the
specified attribute.
Base Switch Object (0x51)
Class Attributes
Attr ID
Access
rule
Name
Data type
Description of attribute
1
Get
Revision
UINT
Revision of this object. The current
value assigned to this values is 1
Instance Attributes
Attr ID
Access
rule
Name
Data type
Description of attribute
1
Get
Device Up
Time
UDINT
Time since device was powered up
(s)
(Note: the value is 32-bit)
2
Get
Total port count
UDINT
Number of physical ports
3
Get
System
Firmware
Version
SHORT_STRING
Human readable representation of
System Firmware Version (Note:
ASCII characters, max length is 32
bytes)
4
Get
Power Source
WORD
Status of switch power source
Bit 0-1: Power Source 1
Bit 2-3: Power Source 2….
Bit 14-15: Power Source 8
00=Not Present (power source not
Summary of Contents for DVS-G928 series
Page 1: ......
Page 12: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual 1 6 _1 MEMO...
Page 15: ...Chapter 2 User Interface Introduction 2 3 2_ You can use to list the commands...
Page 18: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual 2 6 _2 MEMO...
Page 130: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual 3 112 _3 MEMO...
Page 141: ...Chapter 4 IEXplorer Utility Introduction 4 11 4_ MEMO...
Page 142: ...A 1 A Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2...
Page 144: ...Appendix A Private MIB Group A 3 A_ MEMO...
Page 145: ...B 1 B Appendix B MODBUS TCP Map Table of Contents B 1 MODBUS TCP Map B 2...
Page 148: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual B 4 _B MEMO...
Page 206: ...DVS Layer 3 Gigabit Modular Managed Industrial Ethernet Switch User Manual C 58 _C MEMO...