C h a p t e r 2 C o n t r o l R e g i s t e r
2 - 1 3
2_
TU
CR#
TK CH1
Page2
Address
(
Hex
)
TK CH2
Page12
Address
(
Hex
)
Attribute
Name
Description
Default
max. step number to run
#24
058
138
R/W
O
Pattern7_ set up for the
max. step number to run
K0
#25
059
139
R
X
The current cycle index
number of the Pattern
number 0~7 to repeat
running
K0
#26
05A
13A
R/W
O
Temperature wait function
setup
K0~K999 (unit: 0.1)
K9999: disable
K0
#27
05B
13B
R/W
O
Go back to the pattern
number that is currently
running
K0~K7
K0
#28
05C
13C
R/W
O
Go back to the step
number that is currently
running
K0
#29
05D
13D
R/W
O
Time unit of program
control
K0: The unit is 1 min.
K1: The unit is 0.1 sec.
K0
2.1.7
Pattern0, 1 Setup Page
TU
CR#
TK CH1
Page3
Address
(
Hex
)
TK CH2
Page13
Address
(
Hex
)
Attribute
Name
Description
Default
#11
06B
14B
R/W
O
Pattern0-0 Target temperature
Range: K -32768~K32767
K0
#12
06C
14C
R/W
O
Pattern0-1 Target temperature
#13
06D
14D
R/W
O
Pattern0-2 Target temperature
#14
06E
14E
R/W
O
Pattern0-3 Target temperature
#15
06F
14F
R/W
O
Pattern0-4 Target temperature
#16
070
150
R/W
O
Pattern0-5 Target temperature
#17
071
151
R/W
O
Pattern0-6 Target temperature
#18
072
152
R/W
O
Pattern0-7 Target temperature
#19
073
153
R/W
O
Pattern0-0 Running time
Range: K0~K900 Unit
(minutes)
K0
#20
074
154
R/W
O
Pattern0-1 Running time
#21
075
155
R/W
O
Pattern0-2 Running time
#22
076
156
R/W
O
Pattern0-3 Running time
#23
077
157
R/W
O
Pattern0-4 Running time
#24
078
158
R/W
O
Pattern0-5 Running time
#25
079
159
R/W
O
Pattern0-6 Running time
#26
07A
15A
R/W
O
Pattern0-7 Running time