Chapter 4 Communication Protocol
Operating Manual for Communicating Area Sensor
4-16
◎
Example 9. Description of hole detection example
Up and Low installation of two sets of AS-BH080-C, requiring staggered installation of transmitter and receiver.
Register address
Description
Lower grating
Upper grating
00A0H
First shading beam
1
1
00A1H
Final shading beam
80
55
00A2H
The number from the first shading
beam to the final one.
80
55
00A3H
Total length from the first shading
beam to the final one.
160
110
00A4H
The last hole
0
25
00A5H
The last shading
8
29
00A6H
The second last hole
7
6
00A7H
The second last shading
29
20
00A8H
The third last hole
6
0
00A9H
The third last shading
29
0
00AAH
The fourth last hole
0
0
00ABH
The fourth last shading
0
0
00ACH
The fifth last hole
0
0
00ADH
The fifth last shading
0
0
00AEH
The sixth last hole
0
0
Upper
transmitter
Lower
receiver
Lower
transmitter
Upper
receiver