Chapter 4 Communication Protocol
Operating Manual for Communicating Area Sensor
4-5
(Limited to measurement
operation mode)
(Includes version v1031 and
later)
bit = 0, mean non-shading
1
:
bit = 1, mean no-shading
bit = 0, mean shading
*Note
:
The definition is reverse with
0094H
activate upload
mechanism
0096H
R/W
The activate upload in 2
mechanism
(Limited to measurement
operation mode and activate
upload)
(Includes version v1031 and
later)
0 (default)
:
activate upload data
continuously
1: activate upload when any one light
beam status chage
Rapid Light
beams enable
0098H
W
Enable/disable light beams in
measurement rapidly
0: Enable all beams
1: Enable no-shading beams
2: Enable the interval beams between
start beam(0099H) and end
beam(009AH), include start beam and
end beam.
3: Enable the out of interval beams
between start beam(0099H) and end
beam(009AH), not include start beam and
end beam.
Note:
1. make sure all beams on the enable
status before setting
2. before execute 2,3, should execute
start beam and end beam.
0099H
R/W
Set start beam in rapid light
beams enable
1 ~ 128
009AH
R/W
Set endbeam in rapid light
beams enable
1 ~ 128
Hole detection
(Example 9)
00A0H
R
First shading beam
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
FirstOFFCh position of first shading beam
Cannot be used simultaneously with fixed
blanking
00A1H
R
Final shading beam (limited to
mode 2 and 5)
(Includes version v1021 and
LastOFFCh position of final shading
beam
Cannot be used simultaneously with fixed