Chapter 4 Communication Protocol
Operating Manual for Communicating Area Sensor
4-6
later)
blanking
00A2H
R
The number from the first
shading beam to the final one.
(Ignore the hole between the
first shading beam and the
final one)
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
LastOFFCh – Firs 1
Cannot be used simultaneously with fixed
blanking
00A3H
R
Total length from the first
shading beam to the final one.
(Ignore the hole between the
first shading beam and the
final one)
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
(LastOFFCh – Firs 1)* (Beam
pitch)
Unit is cm
Cannot be used simultaneously with fixed
blanking
00A4H
R
The last hole
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
Cannot be used simultaneously with fixed
blanking
00A5H
R
The last shading
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
Cannot be used simultaneously with fixed
blanking
00A6H
R
The second last hole
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
Cannot be used simultaneously with fixed
blanking
00A7H
R
The second last shading
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
Cannot be used simultaneously with fixed
blanking
00A8H
R
The third last hole
(Limited to mode 2 and 5)
(Includes version v1021 and
later)
Cannot be used simultaneously with fixed
blanking
00A9H
R
The third last shading
(Limited to mode 2 and 5)
Cannot be used simultaneously with fixed
blanking