Chapter 4 Communication Protocol
Operating Manual for Communicating Area Sensor
4-4
Set value*0.1=delay time 1 (msec)
008EH
R/W
Setting delay time 2 (1msec)
(Limited to automatic upload
application in measurement
operation mode)
After scanning and data upload, delay the
time of time2
Maximum value is 255; can be used in
coordination with delay time 1.
Set value*1=delay time 2 (msec)
Number of
shading beams
0090H
R
Number of shading beams
(Limited to measurement
operation mode)
Total number of current shading beams. If
fixed blanking is set, the beam will not be
counted.
Shading length 0091H
R
Shading length
(Limited to measurement
operation mode)
Total number of shading beams multiplied
by beam pitch
Unit cm
ON/OFF Delay
0092H
R/W
Output ON Delay
(Limited to measurement
operation mode)
(Includes version v1005 and
later)
When detection is changed from OFF to
ON, the number of consecutive ON must
exceed the number of this setting then
the result will output ON.
Unit is the cycle of one scan (time).
Default value is 0, which means this
function is turned off. Maximum value is
255.
0093H
R/W
Output OFF Delay
(Limited to measurement
operation mode)
(Includes version v1005 and
later)
When detection is changed from ON to
OFF, the number of consecutive OFF
must exceed the number of this setting
then the result will output OFF.
Unit is the cycle of one scan (time).
Default value is 0, which means this
function is turned off. Maximum value is
255.
Invert light
beam state
0094H
R/W
Invert light beam state (Limited
to measurement operation
mode)
(Includes version v1031 and
later)
0060H ~ 006FH light beam state
Definition of light beam state 0 (default)
:
0060H ~ 006FH
bit = 1, mean no-shading
bit = 0, mean shading
1
:
0060H ~ 006FH
bit = 1, mean shading
bit = 0, mean non-shading
Inverter light
beam state in
activate upload
0095H
R/W
Inverter each light beam state
in activate upload, data state
definition(008CH=0)
The definition of light beam state when
008CH=0
0 (default)
:
bit = 1, mean shading