Geo Brick Drive User Manual
Drive Structure and Troubleshooting
272
Geo Brick Drive Specific Online Commands
Type
Function:
Report type of Turbo PMAC
Scope:
Global
Syntax:
TYPE
TYP
Caution
A Geo Brick Drive is malfunctioning or damaged hence unsafe to use,
and may result in equipment damage if AMP is not reported in the
TYPE
command (TURBO2, X4)
This command causes Turbo PMAC to return a string reporting the configuration of the board(s).
Although this is a general Turbo PMAC online command, it will report a unique configuration for Geo
Brick Drives as a text string in the format
TURBO2, AMP, Xn
Where:
TURBO2 indicates that the controller is a Turbo PMAC2, AMP indicates the presence of a Geo Brick
Amplifier, Xn is the multiplication of crystal frequency to CPU frequency (20 MHz).
Example:
X4 value reporting 80 MHz CPU operation.