Geo Brick Drive User Manual
Macro Connectivity
239
20.
Motor Phasing, Open-Loop Test
Motor phasing is performed in the same manner as it would be for any digitally commutated motor.
The following is a satisfactory open loop test:
An erratic or inverted saw tooth response is typically (with quadrature, or sinusoidal encoders) an
indication of reversed encoder direction –with respect to the output command- The encoder decode
parameter can then be changed from 7 to 3 or vice versa. Phasing has to be performed again after this
parameter has been changed.
21.
Tuning the Position-Loop
Tuning the position loop PID gains can be carried out in the traditional manner - see motor setup
section in this manual - there are no special instructions for tuning MACRO motors.
Summary of Contents for Geo Brick