Geo Brick Drive User Manual
Specifications
17
Environmental Specifications
Description
Specifications
Operating Temperature
0 to 45°C
Above 40°C,de-rate current output by 2.5% per °C
Storage Temperature
-25°C to +70°C
Humidity
10% to 90% non-condensing
Operating Altitude
~3300 Feet (1000 m)
De-rate current output by 1.1% per additional 330 feet (100m)
Air Flow Clearances
~3 inches (76.2mm) above and below unit for air flow
Operating Environment
Pollution Degree 2 or equivalent
Protection Specifications
Caution
The internal I
2
T applies to and protects the amplifier power blocks.
The software I
2
T (described in later section) has to be configured
properly to protect against motor/equipment damage.
Description
Specifications
Over Voltage
~ 283 VAC / 400 VDC
Under Voltage
~ 87 VAC / 123 VDC
Over Temperature
~ 80
C
Motor Short Circuit
500 % of rated peak Amps per axis
Over Current
110 % over rated peak Amps per axis
AC Input Phase Loss Detection
Loss of one or more phases (3 Phase operation only)
Shunt Fault Detection
Integrated, I
2
T model
Internal I
2
T protection
2 seconds at peak rated Amps (RMS) per axis
Note
The under voltage fault triggers when the AC Input dips below 87
VAC. However, if this threshold has not been reached (i.e. Low
Voltage/DC operation) the under voltage logic remains unarmed.
Agency Approvals
Description
Specifications
UL
UL508C File E307874
cUL
CSA C22.2 No. 14-05 File E307874
Summary of Contents for Geo Brick
Page 5: ...4...
Page 288: ...Geo Brick Drive User Manual Appendix A 288 Limits Flags J4...