Yaskawa Sigma II 17-Bit Incremental Encoder
Y:$78B21
Y:$78B20
[23-11]
[10-0]
23
[22-6]
[5:4]
3
2
1
0
Incremental Compensation
(11-bits)
Incremental Position in
Single Turn
(17-bits)
U
V
W
Z
Yaskawa Data Registers
Channel 1 Y:$78B20 Channel 5 Y:$78B30
Channel 2 Y:$78B24 Channel 6 Y:$78B34
Channel 3 Y:$78B28 Channel 7 Y:$78B38
Channel 4 Y:$78B2C Channel 8 Y:$78B3C
The on-going servo and commutation position data is setup using a 2-line Entry in the Encoder
Conversion Table. The first line represents a Parallel Y-Word with no filtering ($2) from the
corresponding Yaskawa data register/channel. The second line represents the width of the data to be read
and bit location of the LSB of the data in the source word.
Channel 1, Yaskawa Sigma II 17-bit Incremental Encoder Setup Example