HD32MT.3
- 18 -
V1.2
E
LECTRICAL SAFETY
To protect the equipments (sensors, data logger, optional devices, etc.) and the per-
sonnel operating the weather station is important:
1)
To install a lightning rod on the top of the weather station support tripod or
mast. The lightning rod must be electrically insulated from the tripod/mast and
must be properly connected to ground rods.
2)
To ensure a good protective earth connection of the equipments metallic parts. It
is recommended to connect all the equipments to a single ground point, to avoid
currents generated by several points at different potentials (ground loop) that
may cause measurement errors.