HD32MT.3
- 52 -
V1.2
Atmospheric pressure
HD9408.3B
Precision barometer. Measuring range 0…1350 mbar. Accuracy ± 0.1 hPa
(500…1200 hPa) @ 23 °C. Operating temperature -40…+85 °C. RS485 with
MODBUS-RTU protocol digital output. Power supply 10…30 Vdc. IP 67 housing.
HD4V8TBARO Barometric transmitter. Measuring range 600…1100 mbar. 0…1
Vdc output.
Operating temperature range -30…+60
°C.
Wind speed and direction
HD2003
3-axes static ultrasonic anemometer for the measurement of wind speed and
direction, air temperature, relative humidity and barometric pressure. wind
speed U-V-W cartesian components, sonic temperature. Interfaces available
RS232, RS485 MODBUS-RTU, RS422. Power supply: 12…30 Vdc. To be
mounted on a mast. Free connector included.
HD2003R
HD2003 with heating option.
HD2003.1
3-axes static ultrasonic anemometer for the measurement of wind speed and
direction. wind speed U-V-W cartesian components, sonic temperature. In-
terfaces available RS232, RS485 MODBUS-RTU, RS422. Power supply:
12…30 Vdc. To be mounted on a mast. Free connector included.
HD2003.1R
HD2003.1 with heating option.
CP2003/…
26-pole connection cable with watertight connector on one side, free wires
on the other. L = 5, 10, 15, 20 or 30 m. For HD2003…
HD52.3D…
2-axes static ultrasonic anemometer for the measurement of wind speed and
direction, relative humidity and temperature (optional), diffuse solar radia-
tion (optional) and barometric pressure (optional). RS232, RS485, RS422
and SDI-12 serial outputs, NMEA, MODBUS-RTU and SDI-12 communication
protocols. Heating option available. Power supply: 10…30 Vdc. Installation
on
40 mm external and
36 mm internal mast. Input with 19-pole M23
male connector and 19-pole M23 free female connector. Includes: HD52.3D-
S instrument configuration software, instruction manual.
CP52…
12-wire connection cable with 19-pole M23 female connector on one side, free
wires on the other. L = 5, 10, 15, 20, 30, 50 or 75 m. For HD52.3D…
HD54.3
Cup anemometer. Measuring range: 1…75 m/s. Operating temperature /
humidity: -45…+60 °C / 0…100% RH. Rod mounting. Height 81 mm as-
sembled. With CPM12AA4.5 cable.
HD54.D
Wind direction vane probe. Measuring range: 0…360°. Dead band: typical
4°, maximum 8°. Threshold: 1 m/s. Operating temperature / humidi-
ty: -40…+60 °C / 0…100% RH. Rod mounting. Dimensions: 210 x 120 mm.
With CPM12AA4.5 cable.
HD54.9K
Transverse mast kit for installation of the sensors HD54.3 and HD54.D.
Solar radiation
LP PYRA 10S
"Secondary standard" pyranometer according to ISO 9060 including pro-
tection shield, cartridge for silica gel crystals, 2 spare charges, bubble level
for alignment and Calibration Report. RS485 serial output with MODBUS-RTU
protocol. 5÷30Vdc power supply. Upon request, CPM12-8P… 2, 5 or 10 m
cables with 8-pole M12 female connector.
LP PYRA 02S
First class pyranometer according to ISO 9060. Includes: protection shield,
cartridge for silica gel crystals, 2 spare charges, bubble level for alignment
and Calibration Report. RS485 serial output with MODBUS-RTU protocol.
5÷30Vdc power supply. Upon request, CPM12-8P… 2, 5 or 10 m cables with
8-pole M12 female connector.