HD32MT.3
- 32 -
V1.2
Note: The automatic synchronization function of the clock with a web server requires the pres-
ence of the GSM/UMTS module and is carried out automatically once a day.
11.4
L
OGGING
Command
Description
P
LOGINTERVAL
Prints the value of the logging interval for files of type T3 and T4.
The value is expressed in minutes.
LOGINTERVAL nn
Sets the logging interval for files of type T3 and T4 to value nn
minutes. Accepted values are 1, 2, 5 and 10 minutes.
STOPLOG
Prints how many minutes are left to restart automatically the logging
after a STOPLOG nn command.
STOPLOG nn
Stops logging for nn minutes. The logging will restart automatically
after the number of minutes specified.
The command STOPLOG nn causes the closure of the file T1...T4. Closing the file T3, which is
normally only one on the day of registration if no changes are made to the tables, causes the
generation of additional files of type T3, having name Xn_T3 where n is a sequential number
that increases with each change made to the tables.
The STOPLOG nn command is not accepted if it is sent when the SD card is engaged in other
operations, in which case you must wait until the conclusion of the operation in progress and
repeat the command.
11.5
U
NITS OF MEASUREMENT
Command
Description
P
LISTUNITCODES
Prints the list of the available units of measurement.
0=°C
1=°F
2=%RH
3=g/m
3
4=hPa
5=mmHg 6=inchHg
7=mmH
2
O
8=inchH
2
O 9=atm
10=PSI
11=ftH
2
O
12=kgf/cm
2
13=bar
14=kPa
15=m/s
16=cm/s
17=km/h
18=knot
19=mph
20=mm
21=counts
22=V
23=gradi
24=W/m
2
25=mV
26=status
27=user1
28=user2
29=user3
30=kg
31=g
32=mg
33=mm/minute
34=mm/hour
35=no unit
36=%
TEMPUNIT
Prints the unit of measurement set for the temperature.
TEMPUNIT u
Sets the unit of measurement for temperature.
If u=0 or u=C the unit is °C, if u=1 or u=F the unit is °F.
BAROUNIT
Prints the unit of measurement set for the atmospheric pressure.
BAROUNIT u
Sets the unit of measurement of index u for atmospheric pressure.
The index is between 4 and 14, see the command LISTUNITCODES.
SPEEDUNIT
Prints the unit of measurement set for the wind speed.
SPEEDUNIT u
Sets the unit of measurement of index u for the wind speed.
The index is between 15 and 19, see the command LISTUNITCODES.
USERUNITNAME n
Prints the unit of measurement number n (n = 1,2,3) defined by the
user. These units are user1, user2 and user3 unit corresponding to
the units of index 27, 28 and 29.
If the unit is not set, the data logger responds "? VOID |".
USERUNITNAME n c...c
Set the unit of measurement number n (n = 1,2,3) defined by the
user to the value c...c (the string maximum length is 8 characters).
The unit of measurement of index 26 (status) is associated to the state of ON/OFF sensors, for
example the state of opening/closing of the contact connected to the SW IN.
The units of index 27, 28 and 29 (user1, user2, and user3) are defined by the user with the
command USERUNITNAME. They are provided to associate to the quantities measured by the
sensors connected to the three analog inputs units not included in the list of predefined units