Chapter 4 Parameters
|
4-108
Revision Nov. 2008, VLE1, SW V1.03
11-13
Low-pass Filter Time of Keypad Display
Unit: 0.001
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory Setting: 0.500
Settings
0.001 to 65.535 s
It is used to lower the blinking frequency of LCD display.
11-14
Motor Current at Accel.
Unit: 1
Control
mode
FOCPM
Factory Setting: 150
Settings
50 to 200%
11-15
Elevator Acceleration
Unit: 0.1
Control
mode
FOCPM
Factory Setting: 0.75
Settings
0.60 to 2.00m/s